Lennox Furnace SureLight two-LED control (DS1/DS2) — G40/G50/G51/G60/G61 series DS1 slow flash, DS2 fast flash
What this problem usually means
On Lennox furnaces with the two-LED SureLight control (DS1 red, DS2 green; G40, G50, G51, G60, G61 series), DS1 slow flash with DS2 fast flash means a low flame signal (below 0.2 microamps) — the flame sensor signal is too weak.
Likely causes
- Dirty or oxidized flame sensor
- Poor burner ground
- Weak flame from dirty burners
How to fix it — step by step
- Replace the air filter and open all registers
- Note if the furnace runs but short-cycles
- Reset power once and observe a full cycle
- Call a technician to clean or replace the flame sensor and measure flame current → Shop the flame sensor at RepairClinic
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the flame sensor.
Parts that commonly fix it
- flame sensor - Shop at RepairClinic or Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.
Related Lennox Furnace SureLight two-LED control (DS1/DS2) — G40/G50/G51/G60/G61 series problems
- DS1 slow flash, DS2 off
- DS1 slow flash, DS2 on
- DS1 slow flash, DS2 slow flash (alternating)
- DS1 fast flash, DS2 slow flash
- DS1 off, DS2 slow flash
See all Lennox SureLight two-LED control (DS1/DS2) — G40/G50/G51/G60/G61 series codes & guides →