What this problem usually means

On Lennox furnaces with the two-LED SureLight control (DS1 red, DS2 green; G40, G50, G51, G60, G61 series), DS1 slow flash with DS2 off means flame was sensed without the gas valve energized — a safety fault.

Likely causes

  1. Gas valve leaking or stuck open
  2. Failed control board → Shop the control board at RepairClinic
  3. Shorted flame-sense wiring

How to fix it — step by step

  1. Turn furnace power off and close the gas shutoff to the furnace
  2. Do not keep resetting the furnace
  3. If you smell gas, leave the house and call the gas utility
  4. Call a technician to test the gas valve and control → Shop the gas valve at RepairClinic