Lennox Furnace SureLight two-LED control (DS1/DS2) — G40/G50/G51/G60/G61 series DS1 slow flash, DS2 off
What this problem usually means
On Lennox furnaces with the two-LED SureLight control (DS1 red, DS2 green; G40, G50, G51, G60, G61 series), DS1 slow flash with DS2 off means flame was sensed without the gas valve energized — a safety fault.
Likely causes
- Gas valve leaking or stuck open
- Failed control board → Shop the control board at RepairClinic
- Shorted flame-sense wiring
How to fix it — step by step
- Turn furnace power off and close the gas shutoff to the furnace
- Do not keep resetting the furnace
- If you smell gas, leave the house and call the gas utility
- Call a technician to test the gas valve and control → Shop the gas valve at RepairClinic
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the gas valve.
Shop the gas valve at RepairClinic or Amazon
Also tied to this fault: control board - Shop at RepairClinic or Amazon
Parts that commonly fix it
- gas valve - Shop at RepairClinic or Amazon
- control board - Shop at RepairClinic or Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.
Related Lennox Furnace SureLight two-LED control (DS1/DS2) — G40/G50/G51/G60/G61 series problems
- DS1 slow flash, DS2 on
- DS1 slow flash, DS2 slow flash (alternating)
- DS1 fast flash, DS2 slow flash
- DS1 off, DS2 slow flash
- DS1 slow flash, DS2 fast flash
See all Lennox SureLight two-LED control (DS1/DS2) — G40/G50/G51/G60/G61 series codes & guides →