Kenmore Dryer 796 Series (LG-Built) tE1 Error Code
What the tE1 code means
Temperature sensor failure on Kenmore 796-series (LG-built) dryers: the manual for 796 models lists tE1 or tE2 as a temperature sensor failure, and the 796 steam dryer table lists tE1/tE2 as exhaust thermistor failure.
Likely causes
- Failed exhaust thermistor
- Loose or damaged thermistor wiring
- Main control board fault if thermistor and wiring test good
How to fix it — step by step
- Turn off and unplug the dryer
- Check the exhaust thermistor wiring and reconnect any loose wires → Shop the thermistor at RepairClinic
- Test the thermistor; it should measure about 10,000 ohms at room temperature
- Replace the thermistor if defective; call for service if tE1 returns, as the manual directs
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the thermistor.
Parts that commonly fix the tE1 code
- thermistor - Shop at RepairClinic or Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Kenmore manual is on Kenmore's support site — you'll need your model number.