Kenmore Dryer 796 Series (LG-Built) tE1 Error Code

What the tE1 code means

Temperature sensor failure on Kenmore 796-series (LG-built) dryers: the manual for 796 models lists tE1 or tE2 as a temperature sensor failure, and the 796 steam dryer table lists tE1/tE2 as exhaust thermistor failure.

Likely causes

  1. Failed exhaust thermistor
  2. Loose or damaged thermistor wiring
  3. Main control board fault if thermistor and wiring test good

How to fix it — step by step

  1. Turn off and unplug the dryer
  2. Check the exhaust thermistor wiring and reconnect any loose wires → Shop the thermistor at RepairClinic
  3. Test the thermistor; it should measure about 10,000 ohms at room temperature
  4. Replace the thermistor if defective; call for service if tE1 returns, as the manual directs

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the tE1 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Kenmore manual is on Kenmore's support site — you'll need your model number.

Find your model number inside the door on the frame. It's the key to the right manual pages and the right parts.

Related Kenmore Dryer 796 Series (LG-Built) error codes