Kenmore Dryer 796 Series (LG-Built) PS Error Code
What the PS code means
Power supply error on Kenmore 796-series (LG-built) electric dryers: the power cord is not connected correctly, for example the neutral (white) and L2 (red) wires are on the wrong terminals, so the control protects itself.
Likely causes
- Power cord wired incorrectly at the terminal block
- House power supply incorrect
- Loose power cord connection
How to fix it — step by step
- Turn off power at the breaker and unplug the dryer
- Check the power cord connection at the back of the dryer against the installation instructions → Shop the power cord at RepairClinic
- Correct the wiring or have an electrician do it if you are not confident
- Restore power and try a cycle
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the power cord.
Parts that commonly fix the PS code
- power cord - Shop at RepairClinic or Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Kenmore manual is on Kenmore's support site — you'll need your model number.
Find your model number inside the door on the frame. It's the key to the right manual pages and the right parts.