Kenmore Dryer 796 Series (LG-Built) dE Error Code
What the dE code means
Door switch error on Kenmore 796-series (LG-built) steam dryers: the control cannot confirm the door is closed and working.
Likely causes
- Door not closed firmly
- Clothing caught in the door
- Failed door switch
How to fix it — step by step
- Open the door, check nothing is caught, and close it firmly
- Restart the cycle
- Test the door switch in diagnostic mode if your tech sheet describes it → Shop the door switch at RepairClinic
- Replace the door switch if it does not work
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the door switch.
Parts that commonly fix the dE code
- door switch - Shop at RepairClinic or Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Kenmore manual is on Kenmore's support site — you'll need your model number.
Find your model number inside the door on the frame. It's the key to the right manual pages and the right parts.