Google Nest Thermostat Error Codes

Every help code for Google Nest thermostats, with what each one means and what to do first. E-codes stop the system; N-codes are power warnings. Tap any code for the full walk-through.

Finding your model number: it is on the unit's rating plate.

Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.

Nest Thermostat (2020)

CodeWhat it meansCheck first
E255No heating or cooling detected. W1 or Y1 wire is required.The W1 or Y1 wire is loose, not fully inserted, or has too little exposed copper at the›
E257E257: heat pump requires a Y1 wire. The Nest Thermostat (2020) is configured for a heat pump system but has…Y1 wire not connected at the base (missed during a thermostat swap)›
E258W2 wire requires W1.The W2 wire is loose, not fully inserted, or has too little exposed copper at the›
E260E260: no power to the Y1 wire. The Y1 wire calls for cooling, and the thermostat is seeing no power on it.…Tripped safety cut-out switch on the AC system (including the condensate float switch›
E264Dual fuel requires an alternate heat wire.The alternate heat wire is loose, not fully inserted, or has too little exposed copper›
E269Y2 wire without Y1 wire.The Y2 wire is loose, not fully inserted, or has too little exposed copper at the›
E294E294: R wire is required. The Nest Thermostat (2020) needs an R wire to power itself and switch the system…The R wire is not connected at the base, or not fully seated›
E296No power to Y1 wire detected (cold weather shutoff).The Y1 wire is loose, not fully inserted, or has too little exposed copper at the›
E297E297: C wire or Y1 wire required. The Nest Thermostat (2020) is not getting a usable power path: many systems…No C wire connected, on a system type that cannot power the thermostat without one›
E298E298: no system power. The Nest Thermostat (2020) is not receiving power from the HVAC system. This model…System power off: breaker tripped, service switch off, or furnace door not fully closed›
E299Contact support. Google does not give a wiring cause for this code and directs the user to contact support.The none wire is loose, not fully inserted, or has too little exposed copper at the›
N253No power to W1 wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N254No power to Y1 wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N256No power to G wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N259No power to star/O-B wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N260N260: low power to the thermostat. Google's help lists N260 and N261 together under both of its fixes for…No C wire connected, and the system cannot supply enough trickle power›
N261N261: low power to the thermostat. Google's help lists N261 and N260 together under both of its fixes for…No C wire connected, and the system cannot supply enough trickle power›
N262In extremely cold weather only: No power to Y1 wire detected (cold weather shutoff). Your HVAC system needs…One of the wires in the thermostat is receiving power, but it is less power than›
N263In extremely cold weather only: No power to Y1 wire detected (cold weather shutoff). Your HVAC system needs…One of the wires in the thermostat is receiving power, but it is less power than›
Won't Turn OnA Nest Thermostat (2020) with a blank screen starts with its batteries: unlike the Learning models it runs on…Dead or loose AAA backup batteries after a system power interruption›

Nest Thermostat E

CodeWhat it meansCheck first
E194E194: R wire not detected. The Thermostat E cannot see an R wire connected at all - different from E195…R wire not fully inserted (connector button pops back up)›
E195E195: no power to the R wire detected. The thermostat can see the R wire connected, but no power is arriving…HVAC system power off: breaker tripped, furnace/air handler service switch off, or›
Won't Turn OnA Nest Thermostat E with a dark or frozen screen is almost always a power story: it charges an internal…System power off: breaker, service switch, or furnace door open - the battery drained›

Nest Learning Thermostat (3rd gen)

CodeWhat it meansCheck first
E103E103: overcurrent error on your HVAC equipment. The thermostat detected a wire drawing more current than it…Two thermostat wires touching (nicked insulation in the wall run or at the base)›
E72E72: no power wires detected - an Rc or Rh wire is required. The Learning Thermostat (3rd gen) powers itself…Neither Rc nor Rh actually connected at the base (wire pushed in but not latched, or›
E73E73: no power to the Rc wire detected. The thermostat can see the Rc wire connected, but no power is arriving…HVAC system power off: breaker tripped, furnace/air handler service switch off, or›
E74E74: no power to the Rh wire detected. The thermostat can see the Rh wire connected, but no power is arriving…HVAC system power off: breaker tripped, furnace/air handler service switch off, or›
Won't Turn OnA Learning Thermostat (3rd gen or earlier) with a dark or frozen screen is almost always a power story: it…System power off: breaker, service switch, or furnace door open - the battery drained›

Nest Learning Thermostat (4th gen)

CodeWhat it meansCheck first
E402E402: no power wires detected - an Rc or Rh wire is required. The Learning Thermostat (4th gen) powers itself…Neither Rc nor Rh actually connected at the base (wire pushed in but not latched, or›
E448E448: no system power. The Learning Thermostat (4th gen) is not receiving power from the HVAC system. Google…System power off: breaker tripped, service switch off, or furnace door not fully closed›
Won't Turn OnA Learning Thermostat (4th gen) with a dark screen is almost always a power story, not a dead thermostat: it…System power off: breaker, service switch, or furnace door open - the battery drained›

All models

CodeWhat it meansCheck first
H72H72 is a Heat Link system help code: Google groups it as "H2, H72, or H152" and defines the group in one line…Stand installs: the Nest power cable is not fully inserted, or the wall socket is›
Not Heating or CoolingWhen a Nest thermostat lights up and accepts settings but the heating or cooling never runs, work from the…A help code is showing (E or N series) - the code names the fault: power missing on a›

Nest Learning Thermostat (1st gen)

CodeWhat it meansCheck first
E1Common wire ("C" wire) is required.The C wire is loose, not fully inserted, or has too little exposed copper at the›
E10No power to Y1 wire detected (cold weather shutoff).The Y1 wire is loose, not fully inserted, or has too little exposed copper at the›
E11Heat pump wire O/B detected. No heat pump system present.The O/B wire is loose, not fully inserted, or has too little exposed copper at the›
E12No power to W1 wire detected.The W1 wire is loose, not fully inserted, or has too little exposed copper at the›
E13Too many auxiliary heat wires detected for heat pump.The auxiliary heat wire is loose, not fully inserted, or has too little exposed copper›
E14Dual fuel requires an alternate heat wire.The alternate heat wire is loose, not fully inserted, or has too little exposed copper›
E2No power wires detected. Rc or Rh wire required.The Rc or Rh wire is loose, not fully inserted, or has too little exposed copper at the›
E3No power to Rc wire detected.The Rc wire is loose, not fully inserted, or has too little exposed copper at the›
E4No power to Rh wire detected.The Rh wire is loose, not fully inserted, or has too little exposed copper at the›
E5No heating or cooling detected. W1 or Y1 wire is required.The W1 or Y1 wire is loose, not fully inserted, or has too little exposed copper at the›
E6Too many wires detected. Please remove at least one of O/B, W1, Y1 or AUX.The O/B, W1, Y1 or AUX wire is loose, not fully inserted, or has too little exposed›
E7Y1 wire not detected. A heat pump requires a Y1 wire.The Y1 wire is loose, not fully inserted, or has too little exposed copper at the›
E8Additional wire(s) required. W2/AUX detected by itself.The W2/AUX wire is loose, not fully inserted, or has too little exposed copper at the›
E9No power to C wire detected.The C wire is loose, not fully inserted, or has too little exposed copper at the›
N1Power wire Rc detected. Not connected to equipment.One of the wires in the thermostat is receiving power, but it is less power than›
N2Power wire Rh detected. Not connected to equipment.One of the wires in the thermostat is receiving power, but it is less power than›
N3No power to W1 wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N4No power to Y1 wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N5No power to W2/AUX wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N6No power to G wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N7No power to O/B wire detected.One of the wires in the thermostat is receiving power, but it is less power than›

Nest Learning Thermostat (2nd gen)

CodeWhat it meansCheck first
E22No power wires detected. Rc or Rh wire required.The Rc or Rh wire is loose, not fully inserted, or has too little exposed copper at the›
E23No power to Rc wire detected.The Rc wire is loose, not fully inserted, or has too little exposed copper at the›
E24No power to Rh wire detected.The Rh wire is loose, not fully inserted, or has too little exposed copper at the›
E25No heating or cooling detected. W1 or Y1 wire is required.The W1 or Y1 wire is loose, not fully inserted, or has too little exposed copper at the›
E27Y1 wire not detected. A heat pump requires a Y1 wire.The Y1 wire is loose, not fully inserted, or has too little exposed copper at the›
E28Additional wire(s) required. W2/AUX detected by itself.The W2/AUX wire is loose, not fully inserted, or has too little exposed copper at the›
E29No power to C wire detected.The C wire is loose, not fully inserted, or has too little exposed copper at the›
E30No power to Y1 wire detected (cold weather shutoff).The Y1 wire is loose, not fully inserted, or has too little exposed copper at the›
E32No power to W1 wire detected.The W1 wire is loose, not fully inserted, or has too little exposed copper at the›
E33Too many auxiliary heat wires detected for heat pump.The auxiliary heat wire is loose, not fully inserted, or has too little exposed copper›
E34Dual fuel requires an alternate heat wire.The alternate heat wire is loose, not fully inserted, or has too little exposed copper›
E35Dual fuel can have at most 2 alternate heat wires.The alternate heat wire is loose, not fully inserted, or has too little exposed copper›
E36Too many auxiliary heat wires detected for heat pump.The auxiliary heat wire is loose, not fully inserted, or has too little exposed copper›
N21Power wire Rc detected. Not connected to equipment.One of the wires in the thermostat is receiving power, but it is less power than›
N22Power wire Rh detected. Not connected to equipment.One of the wires in the thermostat is receiving power, but it is less power than›
N23No power to W1 wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N24No power to Y1 wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N25No power to W2/AUX wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N26No power to G wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N27No power to O/B wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N28No power to Y2 wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N29No power to star wire detected.One of the wires in the thermostat is receiving power, but it is less power than›

Nest Learning Thermostat (3rd gen)

CodeWhat it meansCheck first
E102The Nest thermostat detected an overcurrent error on your HVAC equipment.The equipment wire is loose, not fully inserted, or has too little exposed copper at›
E104The Nest thermostat detected an overcurrent error on your HVAC equipment.The equipment wire is loose, not fully inserted, or has too little exposed copper at›
E105The Nest thermostat detected an overcurrent error on your HVAC equipment.The equipment wire is loose, not fully inserted, or has too little exposed copper at›
E106The Nest thermostat detected an overcurrent error on your HVAC equipment.The equipment wire is loose, not fully inserted, or has too little exposed copper at›
E107The Nest thermostat detected an overcurrent error on your HVAC equipment.The equipment wire is loose, not fully inserted, or has too little exposed copper at›
E108The Nest thermostat detected an overcurrent error on your HVAC equipment.The equipment wire is loose, not fully inserted, or has too little exposed copper at›
E116No power to Y1 wire detected (cold weather shutoff).The Y1 wire is loose, not fully inserted, or has too little exposed copper at the›
E37Too many auxiliary heat wires detected for heat pump.The auxiliary heat wire is loose, not fully inserted, or has too little exposed copper›
E38Too many auxiliary heat wires detected for heat pump.The auxiliary heat wire is loose, not fully inserted, or has too little exposed copper›
E39Y2 wire without Y1 wire.The Y2 wire is loose, not fully inserted, or has too little exposed copper at the›
E40W3 wire without W2/AUX wire.The W3 wire is loose, not fully inserted, or has too little exposed copper at the›
E41E wire without O/B wire.The E wire is loose, not fully inserted, or has too little exposed copper at the›
E52The Nest thermostat detected an overcurrent error on your HVAC equipment.The equipment wire is loose, not fully inserted, or has too little exposed copper at›
E53The Nest thermostat detected an overcurrent error on your HVAC equipment.The equipment wire is loose, not fully inserted, or has too little exposed copper at›
E54The Nest thermostat detected an overcurrent error on your HVAC equipment.The equipment wire is loose, not fully inserted, or has too little exposed copper at›
E55The Nest thermostat detected an overcurrent error on your HVAC equipment.The equipment wire is loose, not fully inserted, or has too little exposed copper at›
E56The Nest thermostat detected an overcurrent error on your HVAC equipment.The equipment wire is loose, not fully inserted, or has too little exposed copper at›
E57The Nest thermostat detected an overcurrent error on your HVAC equipment.The equipment wire is loose, not fully inserted, or has too little exposed copper at›
E58The Nest thermostat detected an overcurrent error on your HVAC equipment.The equipment wire is loose, not fully inserted, or has too little exposed copper at›
E66No power to Y1 wire detected (cold weather shutoff).The Y1 wire is loose, not fully inserted, or has too little exposed copper at the›
E75No heating or cooling detected. W1 or Y1 wire is required.The W1 or Y1 wire is loose, not fully inserted, or has too little exposed copper at the›
E77Y1 wire not detected. A heat pump requires a Y1 wire.The Y1 wire is loose, not fully inserted, or has too little exposed copper at the›
E78Additional wire(s) required. W2/AUX detected by itself.The W2/AUX wire is loose, not fully inserted, or has too little exposed copper at the›
E79No power to C wire detected.The C wire is loose, not fully inserted, or has too little exposed copper at the›
E80No power to Y1 wire detected (cold weather shutoff).The Y1 wire is loose, not fully inserted, or has too little exposed copper at the›
E82No power to W1 wire detected.The W1 wire is loose, not fully inserted, or has too little exposed copper at the›
E83Too many auxiliary heat wires detected for heat pump.The auxiliary heat wire is loose, not fully inserted, or has too little exposed copper›
E84Dual fuel requires an alternate heat wire.The alternate heat wire is loose, not fully inserted, or has too little exposed copper›
E85Dual fuel can have at most 2 alternate heat wires.The alternate heat wire is loose, not fully inserted, or has too little exposed copper›
E86Too many auxiliary heat wires detected for heat pump.The auxiliary heat wire is loose, not fully inserted, or has too little exposed copper›
E87Too many auxiliary heat wires detected for heat pump.The auxiliary heat wire is loose, not fully inserted, or has too little exposed copper›
E88Too many auxiliary heat wires detected for heat pump.The auxiliary heat wire is loose, not fully inserted, or has too little exposed copper›
E89Y2 wire without Y1 wire.The Y2 wire is loose, not fully inserted, or has too little exposed copper at the›
E90W3 wire without W2/AUX wire.The W3 wire is loose, not fully inserted, or has too little exposed copper at the›
E91E wire without O/B wire.The E wire is loose, not fully inserted, or has too little exposed copper at the›
N71Power wire Rc detected. Not connected to equipment.One of the wires in the thermostat is receiving power, but it is less power than›
N72Power wire Rh detected. Not connected to equipment.One of the wires in the thermostat is receiving power, but it is less power than›
N73No power to W1 wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N74No power to Y1 wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N75No power to W2/AUX wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N76No power to G wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N77No power to O/B wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N78No power to Y2 wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N79No power to star wire detected.One of the wires in the thermostat is receiving power, but it is less power than›

Nest Learning Thermostat (4th gen)

CodeWhat it meansCheck first
E405No heating or cooling detected. W1 or Y1 wire is required.The W1 or Y1 wire is loose, not fully inserted, or has too little exposed copper at the›
E407Y1 wire not detected. A heat pump requires a Y1 wire.The Y1 wire is loose, not fully inserted, or has too little exposed copper at the›
E408Additional wire(s) required. W2/AUX detected by itself.The W2/AUX wire is loose, not fully inserted, or has too little exposed copper at the›
E413Too many auxiliary heat wires detected for heat pump.The auxiliary heat wire is loose, not fully inserted, or has too little exposed copper›
E414Dual fuel requires an alternate heat wire.The alternate heat wire is loose, not fully inserted, or has too little exposed copper›
E419Y2 wire without Y1 wire.The Y2 wire is loose, not fully inserted, or has too little exposed copper at the›
E420W3 wire without W2/AUX wire.The W3 wire is loose, not fully inserted, or has too little exposed copper at the›
E421E wire without O/B wire.The E wire is loose, not fully inserted, or has too little exposed copper at the›
E439G2 detected. G1 wire is also required.The G2 wire is loose, not fully inserted, or has too little exposed copper at the›
E440G2 wire detected. Remove W2/AUX wire.The G2 wire is loose, not fully inserted, or has too little exposed copper at the›
E442G or G3 wire detected. G1 and G2 are also required.The G or G3 wire is loose, not fully inserted, or has too little exposed copper at the›
E443G2 and O/B wire conflict.The G2 and O/B wire is loose, not fully inserted, or has too little exposed copper at›
E450AQ and star wire conflict.The AQ and star wire is loose, not fully inserted, or has too little exposed copper at›
E451Dual transformers require Y3 on AQ+.The Y3 wire is loose, not fully inserted, or has too little exposed copper at the›
E452Y3 requires Y2.The Y3 wire is loose, not fully inserted, or has too little exposed copper at the›
N401Power wire Rc detected. Not connected to equipment.One of the wires in the thermostat is receiving power, but it is less power than›
N402Power wire Rh detected. Not connected to equipment.One of the wires in the thermostat is receiving power, but it is less power than›
N403No power to W1 wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N404No power to Y1 wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N405No power to W2/AUX wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N406No power to G wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N407No power to O/B wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N408No power to Y2 wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N409No power to star wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N410A C wire or Nest Power Connector is recommended for your thermostat.One of the wires in the thermostat is receiving power, but it is less power than›
N411Low power to C wire.One of the wires in the thermostat is receiving power, but it is less power than›
N412In extremely cold weather only: No power to Y1 wire detected (cold weather shutoff). Your HVAC system needs…One of the wires in the thermostat is receiving power, but it is less power than›
N413In extremely cold weather only: No power to Y1 wire detected (cold weather shutoff). Your HVAC system needs…One of the wires in the thermostat is receiving power, but it is less power than›
N414No power to AQ+ wire detected for a 1-wire accessory (AQ- not connected). AQ+ is an additional terminal for…One of the wires in the thermostat is receiving power, but it is less power than›
N415AQ- wire requires AQ+ wire. AQ is an additional terminal for accessory wires like humidifiers and…One of the wires in the thermostat is receiving power, but it is less power than›
N416The Nest thermostat detected an overvoltage or overcurrent error on your HVAC equipment. Your HVAC system may…One of the wires in the thermostat is receiving power, but it is less power than›
N417The Nest thermostat detected an overvoltage or overcurrent error on your HVAC equipment. Your HVAC system may…One of the wires in the thermostat is receiving power, but it is less power than›
N418The Nest thermostat detected an overvoltage or overcurrent error on your HVAC equipment. Your HVAC system may…One of the wires in the thermostat is receiving power, but it is less power than›
N419The Nest thermostat detected an overvoltage or overcurrent error on your HVAC equipment. Your HVAC system may…One of the wires in the thermostat is receiving power, but it is less power than›
N420The Nest thermostat detected an overvoltage or overcurrent error on your HVAC equipment. Your HVAC system may…One of the wires in the thermostat is receiving power, but it is less power than›
N421The Nest thermostat detected an overvoltage or overcurrent error on your HVAC equipment. Your HVAC system may…One of the wires in the thermostat is receiving power, but it is less power than›
N422The Nest thermostat detected an overvoltage or overcurrent error on your HVAC equipment. Your HVAC system may…One of the wires in the thermostat is receiving power, but it is less power than›
N423The Nest thermostat detected an overvoltage or overcurrent error on your HVAC equipment. Your HVAC system may…One of the wires in the thermostat is receiving power, but it is less power than›

Nest Thermostat E

CodeWhat it meansCheck first
E155No heating or cooling detected. W1 or Y1 wire is required.The W1 or Y1 wire is loose, not fully inserted, or has too little exposed copper at the›
E157Y1 wire not detected.The Y1 wire is loose, not fully inserted, or has too little exposed copper at the›
E158W1 wire not detected.The W1 wire is loose, not fully inserted, or has too little exposed copper at the›
E159No power to C wire detected.The C wire is loose, not fully inserted, or has too little exposed copper at the›
E160No power to Y1 wire detected (cold weather shutoff).The Y1 wire is loose, not fully inserted, or has too little exposed copper at the›
E162No power to W1 wire detected.The W1 wire is loose, not fully inserted, or has too little exposed copper at the›
E164Dual fuel requires an alternate heat wire.The alternate heat wire is loose, not fully inserted, or has too little exposed copper›
E169Y2 wire without Y1 wire.The Y2 wire is loose, not fully inserted, or has too little exposed copper at the›
E182The Nest thermostat detected an overcurrent error on your HVAC equipment.The equipment wire is loose, not fully inserted, or has too little exposed copper at›
E183The Nest thermostat detected an overcurrent error on your HVAC equipment.The equipment wire is loose, not fully inserted, or has too little exposed copper at›
E184Check G wire.The G wire is loose, not fully inserted, or has too little exposed copper at the›
E188The Nest thermostat detected an overcurrent error on your HVAC equipment.The equipment wire is loose, not fully inserted, or has too little exposed copper at›
E196No power to Y1 wire detected (cold weather shutoff).The Y1 wire is loose, not fully inserted, or has too little exposed copper at the›
N153No power to W1 wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N154No power to Y1 wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N156No power to G wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N159No power to star wire detected.One of the wires in the thermostat is receiving power, but it is less power than›

Common questions

What is the difference between Nest codes N260 and N261?
Very little: Google lists them together because both mean the thermostat is low on power. The fixes are the same: sort out the C wire, or fit a Nest Power Connector so the thermostat gets steady power instead of borrowing it from the heating circuit.

What does E195 mean on a Nest thermostat?
No power is arriving on the R wire. The thermostat can see the wire connected, but without power on it the thermostat cannot call for heat or cooling. Check the furnace's power switch, breaker and blower door first: a dead furnace means a dead R wire.

Does my Nest thermostat need a C wire?
Not always, but most N-code warnings (N260, N261) and many E-code power faults end there. A C wire, or the Nest Power Connector, gives the thermostat constant power and stops it borrowing charge from the heating and cooling circuits.

Looking for a part?

Once you know the part you need, browse Google Nest Thermostat replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.