Google Nest Thermostat Learning Thermostat (3rd gen) E103 Error Code

What the E103 code means

E103: overcurrent error on your HVAC equipment. The thermostat detected a wire drawing more current than it should. Google lists E103 in its overcurrent family (E52-E58, E102-E108, E182, E183, E188), and an overcurrent fault lives on the equipment side far more often than in the thermostat: a shorted wire, a failing contactor or valve coil, or a component beginning to seize. Do not keep clearing and retrying it - repeated overcurrent can damage the thermostat.

Likely causes

  1. Two thermostat wires touching (nicked insulation in the wall run or at the base)
  2. A failing component on the HVAC equipment drawing excess current (contactor coil, zone valve, blower relay)
  3. A wire landed on the wrong connector, energizing a circuit it should not
  4. Water or corrosion bridging terminals at the equipment

How to fix it — step by step

  1. Turn off power to the system at the breaker. Pull the display off the base and inspect every wire: fully inserted in its own connector, no stray copper strands touching a neighbour, no nicked or melted insulation. Fix anything you find.
  2. Compare the wiring against the photo of your old thermostat's wiring (or the equipment's wiring diagram): a wire on the wrong terminal after a thermostat swap is a common overcurrent cause.
  3. Restore power and call for heat or cool once. If E103 does not return, the wiring fault was the cause - monitor it over the next few cycles.
  4. If E103 returns with proven wiring, the overcurrent is inside the HVAC equipment. Stop retrying and book an HVAC technician: tell them the thermostat reported an overcurrent code, which points them at the contactor, valves and control board rather than the thermostat.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the E103 code

No specific replacement part is documented for this fault. If the checks above do not clear it, your thermostat likely needs to be disassembled and an internal part replaced - and since the manufacturer publishes no procedure for that, it is the point where most owners hand it to a repair shop.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manufacturer documentation

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Google Nest Thermostat Learning Thermostat (3rd gen) error codes

See all Google Nest Learning Thermostat (3rd gen) codes & guides →