Google Nest Nest Learning Thermostat (4th gen) Error Codes

Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 38 codes covered.

Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.

CodeWhat it meansCheck first
E405No heating or cooling detected. W1 or Y1 wire is required.The W1 or Y1 wire is loose, not fully inserted, or has too little exposed copper at the›
E407Y1 wire not detected. A heat pump requires a Y1 wire.The Y1 wire is loose, not fully inserted, or has too little exposed copper at the›
E408Additional wire(s) required. W2/AUX detected by itself.The W2/AUX wire is loose, not fully inserted, or has too little exposed copper at the›
E413Too many auxiliary heat wires detected for heat pump.The auxiliary heat wire is loose, not fully inserted, or has too little exposed copper›
E414Dual fuel requires an alternate heat wire.The alternate heat wire is loose, not fully inserted, or has too little exposed copper›
E419Y2 wire without Y1 wire.The Y2 wire is loose, not fully inserted, or has too little exposed copper at the›
E420W3 wire without W2/AUX wire.The W3 wire is loose, not fully inserted, or has too little exposed copper at the›
E421E wire without O/B wire.The E wire is loose, not fully inserted, or has too little exposed copper at the›
E439G2 detected. G1 wire is also required.The G2 wire is loose, not fully inserted, or has too little exposed copper at the›
E440G2 wire detected. Remove W2/AUX wire.The G2 wire is loose, not fully inserted, or has too little exposed copper at the›
E442G or G3 wire detected. G1 and G2 are also required.The G or G3 wire is loose, not fully inserted, or has too little exposed copper at the›
E443G2 and O/B wire conflict.The G2 and O/B wire is loose, not fully inserted, or has too little exposed copper at›
E450AQ and star wire conflict.The AQ and star wire is loose, not fully inserted, or has too little exposed copper at›
E451Dual transformers require Y3 on AQ+.The Y3 wire is loose, not fully inserted, or has too little exposed copper at the›
E452Y3 requires Y2.The Y3 wire is loose, not fully inserted, or has too little exposed copper at the›
N401Power wire Rc detected. Not connected to equipment.One of the wires in the thermostat is receiving power, but it is less power than›
N402Power wire Rh detected. Not connected to equipment.One of the wires in the thermostat is receiving power, but it is less power than›
N403No power to W1 wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N404No power to Y1 wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N405No power to W2/AUX wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N406No power to G wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N407No power to O/B wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N408No power to Y2 wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N409No power to star wire detected.One of the wires in the thermostat is receiving power, but it is less power than›
N410A C wire or Nest Power Connector is recommended for your thermostat.One of the wires in the thermostat is receiving power, but it is less power than›
N411Low power to C wire.One of the wires in the thermostat is receiving power, but it is less power than›
N412In extremely cold weather only: No power to Y1 wire detected (cold weather shutoff). Your HVAC system needs…One of the wires in the thermostat is receiving power, but it is less power than›
N413In extremely cold weather only: No power to Y1 wire detected (cold weather shutoff). Your HVAC system needs…One of the wires in the thermostat is receiving power, but it is less power than›
N414No power to AQ+ wire detected for a 1-wire accessory (AQ- not connected). AQ+ is an additional terminal for…One of the wires in the thermostat is receiving power, but it is less power than›
N415AQ- wire requires AQ+ wire. AQ is an additional terminal for accessory wires like humidifiers and…One of the wires in the thermostat is receiving power, but it is less power than›
N416The Nest thermostat detected an overvoltage or overcurrent error on your HVAC equipment. Your HVAC system may…One of the wires in the thermostat is receiving power, but it is less power than›
N417The Nest thermostat detected an overvoltage or overcurrent error on your HVAC equipment. Your HVAC system may…One of the wires in the thermostat is receiving power, but it is less power than›
N418The Nest thermostat detected an overvoltage or overcurrent error on your HVAC equipment. Your HVAC system may…One of the wires in the thermostat is receiving power, but it is less power than›
N419The Nest thermostat detected an overvoltage or overcurrent error on your HVAC equipment. Your HVAC system may…One of the wires in the thermostat is receiving power, but it is less power than›
N420The Nest thermostat detected an overvoltage or overcurrent error on your HVAC equipment. Your HVAC system may…One of the wires in the thermostat is receiving power, but it is less power than›
N421The Nest thermostat detected an overvoltage or overcurrent error on your HVAC equipment. Your HVAC system may…One of the wires in the thermostat is receiving power, but it is less power than›
N422The Nest thermostat detected an overvoltage or overcurrent error on your HVAC equipment. Your HVAC system may…One of the wires in the thermostat is receiving power, but it is less power than›
N423The Nest thermostat detected an overvoltage or overcurrent error on your HVAC equipment. Your HVAC system may…One of the wires in the thermostat is receiving power, but it is less power than›

All Google Nest thermostat models & codes →

Looking for a part?

Once you know the part you need, browse Google Nest Nest Learning Thermostat (4th gen) replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.