Google Nest Nest Learning Thermostat (2nd gen) Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 22 codes covered.
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
| Code | What it means | Check first | |
|---|---|---|---|
| E22 | No power wires detected. Rc or Rh wire required. | The Rc or Rh wire is loose, not fully inserted, or has too little exposed copper at the | › |
| E23 | No power to Rc wire detected. | The Rc wire is loose, not fully inserted, or has too little exposed copper at the | › |
| E24 | No power to Rh wire detected. | The Rh wire is loose, not fully inserted, or has too little exposed copper at the | › |
| E25 | No heating or cooling detected. W1 or Y1 wire is required. | The W1 or Y1 wire is loose, not fully inserted, or has too little exposed copper at the | › |
| E27 | Y1 wire not detected. A heat pump requires a Y1 wire. | The Y1 wire is loose, not fully inserted, or has too little exposed copper at the | › |
| E28 | Additional wire(s) required. W2/AUX detected by itself. | The W2/AUX wire is loose, not fully inserted, or has too little exposed copper at the | › |
| E29 | No power to C wire detected. | The C wire is loose, not fully inserted, or has too little exposed copper at the | › |
| E30 | No power to Y1 wire detected (cold weather shutoff). | The Y1 wire is loose, not fully inserted, or has too little exposed copper at the | › |
| E32 | No power to W1 wire detected. | The W1 wire is loose, not fully inserted, or has too little exposed copper at the | › |
| E33 | Too many auxiliary heat wires detected for heat pump. | The auxiliary heat wire is loose, not fully inserted, or has too little exposed copper | › |
| E34 | Dual fuel requires an alternate heat wire. | The alternate heat wire is loose, not fully inserted, or has too little exposed copper | › |
| E35 | Dual fuel can have at most 2 alternate heat wires. | The alternate heat wire is loose, not fully inserted, or has too little exposed copper | › |
| E36 | Too many auxiliary heat wires detected for heat pump. | The auxiliary heat wire is loose, not fully inserted, or has too little exposed copper | › |
| N21 | Power wire Rc detected. Not connected to equipment. | One of the wires in the thermostat is receiving power, but it is less power than | › |
| N22 | Power wire Rh detected. Not connected to equipment. | One of the wires in the thermostat is receiving power, but it is less power than | › |
| N23 | No power to W1 wire detected. | One of the wires in the thermostat is receiving power, but it is less power than | › |
| N24 | No power to Y1 wire detected. | One of the wires in the thermostat is receiving power, but it is less power than | › |
| N25 | No power to W2/AUX wire detected. | One of the wires in the thermostat is receiving power, but it is less power than | › |
| N26 | No power to G wire detected. | One of the wires in the thermostat is receiving power, but it is less power than | › |
| N27 | No power to O/B wire detected. | One of the wires in the thermostat is receiving power, but it is less power than | › |
| N28 | No power to Y2 wire detected. | One of the wires in the thermostat is receiving power, but it is less power than | › |
| N29 | No power to star wire detected. | One of the wires in the thermostat is receiving power, but it is less power than | › |
All Google Nest thermostat models & codes →
Looking for a part?
Once you know the part you need, browse Google Nest Nest Learning Thermostat (2nd gen) replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.