Google Nest Nest Learning Thermostat (1st gen) Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 21 codes covered.
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
| Code | What it means | Check first | |
|---|---|---|---|
| E1 | Common wire ("C" wire) is required. | The C wire is loose, not fully inserted, or has too little exposed copper at the | › |
| E10 | No power to Y1 wire detected (cold weather shutoff). | The Y1 wire is loose, not fully inserted, or has too little exposed copper at the | › |
| E11 | Heat pump wire O/B detected. No heat pump system present. | The O/B wire is loose, not fully inserted, or has too little exposed copper at the | › |
| E12 | No power to W1 wire detected. | The W1 wire is loose, not fully inserted, or has too little exposed copper at the | › |
| E13 | Too many auxiliary heat wires detected for heat pump. | The auxiliary heat wire is loose, not fully inserted, or has too little exposed copper | › |
| E14 | Dual fuel requires an alternate heat wire. | The alternate heat wire is loose, not fully inserted, or has too little exposed copper | › |
| E2 | No power wires detected. Rc or Rh wire required. | The Rc or Rh wire is loose, not fully inserted, or has too little exposed copper at the | › |
| E3 | No power to Rc wire detected. | The Rc wire is loose, not fully inserted, or has too little exposed copper at the | › |
| E4 | No power to Rh wire detected. | The Rh wire is loose, not fully inserted, or has too little exposed copper at the | › |
| E5 | No heating or cooling detected. W1 or Y1 wire is required. | The W1 or Y1 wire is loose, not fully inserted, or has too little exposed copper at the | › |
| E6 | Too many wires detected. Please remove at least one of O/B, W1, Y1 or AUX. | The O/B, W1, Y1 or AUX wire is loose, not fully inserted, or has too little exposed | › |
| E7 | Y1 wire not detected. A heat pump requires a Y1 wire. | The Y1 wire is loose, not fully inserted, or has too little exposed copper at the | › |
| E8 | Additional wire(s) required. W2/AUX detected by itself. | The W2/AUX wire is loose, not fully inserted, or has too little exposed copper at the | › |
| E9 | No power to C wire detected. | The C wire is loose, not fully inserted, or has too little exposed copper at the | › |
| N1 | Power wire Rc detected. Not connected to equipment. | One of the wires in the thermostat is receiving power, but it is less power than | › |
| N2 | Power wire Rh detected. Not connected to equipment. | One of the wires in the thermostat is receiving power, but it is less power than | › |
| N3 | No power to W1 wire detected. | One of the wires in the thermostat is receiving power, but it is less power than | › |
| N4 | No power to Y1 wire detected. | One of the wires in the thermostat is receiving power, but it is less power than | › |
| N5 | No power to W2/AUX wire detected. | One of the wires in the thermostat is receiving power, but it is less power than | › |
| N6 | No power to G wire detected. | One of the wires in the thermostat is receiving power, but it is less power than | › |
| N7 | No power to O/B wire detected. | One of the wires in the thermostat is receiving power, but it is less power than | › |
All Google Nest thermostat models & codes →