Google Nest Nest Thermostat Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 20 codes covered.
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
| Code | What it means | Check first | |
|---|---|---|---|
| E255 | No heating or cooling detected. W1 or Y1 wire is required. | The W1 or Y1 wire is loose, not fully inserted, or has too little exposed copper at the | › |
| E257 | E257: heat pump requires a Y1 wire. The Nest Thermostat (2020) is configured for a heat pump system but has… | Y1 wire not connected at the base (missed during a thermostat swap) | › |
| E258 | W2 wire requires W1. | The W2 wire is loose, not fully inserted, or has too little exposed copper at the | › |
| E260 | E260: no power to the Y1 wire. The Y1 wire calls for cooling, and the thermostat is seeing no power on it.… | Tripped safety cut-out switch on the AC system (including the condensate float switch | › |
| E264 | Dual fuel requires an alternate heat wire. | The alternate heat wire is loose, not fully inserted, or has too little exposed copper | › |
| E269 | Y2 wire without Y1 wire. | The Y2 wire is loose, not fully inserted, or has too little exposed copper at the | › |
| E294 | E294: R wire is required. The Nest Thermostat (2020) needs an R wire to power itself and switch the system… | The R wire is not connected at the base, or not fully seated | › |
| E296 | No power to Y1 wire detected (cold weather shutoff). | The Y1 wire is loose, not fully inserted, or has too little exposed copper at the | › |
| E297 | E297: C wire or Y1 wire required. The Nest Thermostat (2020) is not getting a usable power path: many systems… | No C wire connected, on a system type that cannot power the thermostat without one | › |
| E298 | E298: no system power. The Nest Thermostat (2020) is not receiving power from the HVAC system. This model… | System power off: breaker tripped, service switch off, or furnace door not fully closed | › |
| E299 | Contact support. Google does not give a wiring cause for this code and directs the user to contact support. | The none wire is loose, not fully inserted, or has too little exposed copper at the | › |
| N253 | No power to W1 wire detected. | One of the wires in the thermostat is receiving power, but it is less power than | › |
| N254 | No power to Y1 wire detected. | One of the wires in the thermostat is receiving power, but it is less power than | › |
| N256 | No power to G wire detected. | One of the wires in the thermostat is receiving power, but it is less power than | › |
| N259 | No power to star/O-B wire detected. | One of the wires in the thermostat is receiving power, but it is less power than | › |
| N260 | N260: low power to the thermostat. Google's help lists N260 and N261 together under both of its fixes for… | No C wire connected, and the system cannot supply enough trickle power | › |
| N261 | N261: low power to the thermostat. Google's help lists N261 and N260 together under both of its fixes for… | No C wire connected, and the system cannot supply enough trickle power | › |
| N262 | In extremely cold weather only: No power to Y1 wire detected (cold weather shutoff). Your HVAC system needs… | One of the wires in the thermostat is receiving power, but it is less power than | › |
| N263 | In extremely cold weather only: No power to Y1 wire detected (cold weather shutoff). Your HVAC system needs… | One of the wires in the thermostat is receiving power, but it is less power than | › |
| Won't Turn On | A Nest Thermostat (2020) with a blank screen starts with its batteries: unlike the Learning models it runs on… | Dead or loose AAA backup batteries after a system power interruption | › |
All Google Nest thermostat models & codes →
Looking for a part?
Once you know the part you need, browse Google Nest Nest Thermostat replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.