Crown Boiler Aruba 5 series Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 15 codes covered.
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
| Code | What it means | Check first | |
|---|---|---|---|
| 18 | Error 18 is an internal electronics failure in the boiler control. The manual's direction is direct: cycle… | Internal problem with the boiler control | › |
| 23 | Error 23 means flame was sensed during the 1.7 second pre-purge, before the pilot valve opened. Flame proof… | Defective gas valve | › |
| 32 | Error 32 is a boiler water temperature sensor failure. The control cannot trust the water temperature… | Loose sensor connection at the control | › |
| 4 | Error 4 is a low flame signal. The pilot lit but the flame proof reaching the control is too weak to trust… | Low gas pressure at the gas valve inlet | › |
| 55 | Error 55 means the vent damper failed to open after 60 seconds. The boiler will not fire with the damper… | Loose or defective damper harness | › |
| 56 | Error 56 means power is present at the end of the limit string when it should not be. The manual names the… | Defective boiler control | › |
| 57 | Error 57 is a grounded pilot electrode. Something is shorting the pilot electrode to ground: condensate or… | Condensate or foreign material shorting the pilot electrode to ground | › |
| 58 | Error 58 is an AC power frequency error. The control expects a 60 Hz supply and is not seeing it, or the… | 120 VAC supply frequency incorrect (should be 60 Hz) | › |
| 59 | Error 59 is a line voltage error: the supply voltage is too high or too low. The boiler wants 120 VAC… | Power supply voltage incorrect (should be 120 VAC nominal) | › |
| 6 | Error 6 means a pilot flame was detected when no flame should be present. The control sees flame proof with… | Defective gas valve leaking gas through | › |
| 60 | Error 60 means the thermostat input is higher than its threshold. External voltage is being applied to the… | External voltage applied to the thermostat connections | › |
| 61 | Error 61 is an unstable line voltage. The incoming 120 VAC supply is dirty or swinging, loose connections… | Dirty 120 VAC power supply | › |
| 63 | Error 63 means maximum recycles were exceeded: the boiler lost proof of pilot six times in a row, the same… | Repeated loss of pilot proof (see Error 4 causes) | › |
| 64 | Error 64 is an internal failure code tied to the damper and pilot checks. The manual lists a loose or… | Loose or defective damper harness | › |
| 89 | Error 89 means EnviraCom communication has been lost between the boiler control and certain Crown control… | Communication lost between the boiler control and a Crown control option | › |
All Crown Boiler boiler models & codes →
Looking for a part?
Once you know the part you need, browse Crown Boiler Aruba 5 series replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.