Crown Boiler Aruba 5 series Error Codes

Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 15 codes covered.

Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.

CodeWhat it meansCheck first
18Error 18 is an internal electronics failure in the boiler control. The manual's direction is direct: cycle…Internal problem with the boiler control›
23Error 23 means flame was sensed during the 1.7 second pre-purge, before the pilot valve opened. Flame proof…Defective gas valve›
32Error 32 is a boiler water temperature sensor failure. The control cannot trust the water temperature…Loose sensor connection at the control›
4Error 4 is a low flame signal. The pilot lit but the flame proof reaching the control is too weak to trust…Low gas pressure at the gas valve inlet›
55Error 55 means the vent damper failed to open after 60 seconds. The boiler will not fire with the damper…Loose or defective damper harness›
56Error 56 means power is present at the end of the limit string when it should not be. The manual names the…Defective boiler control›
57Error 57 is a grounded pilot electrode. Something is shorting the pilot electrode to ground: condensate or…Condensate or foreign material shorting the pilot electrode to ground›
58Error 58 is an AC power frequency error. The control expects a 60 Hz supply and is not seeing it, or the…120 VAC supply frequency incorrect (should be 60 Hz)›
59Error 59 is a line voltage error: the supply voltage is too high or too low. The boiler wants 120 VAC…Power supply voltage incorrect (should be 120 VAC nominal)›
6Error 6 means a pilot flame was detected when no flame should be present. The control sees flame proof with…Defective gas valve leaking gas through›
60Error 60 means the thermostat input is higher than its threshold. External voltage is being applied to the…External voltage applied to the thermostat connections›
61Error 61 is an unstable line voltage. The incoming 120 VAC supply is dirty or swinging, loose connections…Dirty 120 VAC power supply›
63Error 63 means maximum recycles were exceeded: the boiler lost proof of pilot six times in a row, the same…Repeated loss of pilot proof (see Error 4 causes)›
64Error 64 is an internal failure code tied to the damper and pilot checks. The manual lists a loose or…Loose or defective damper harness›
89Error 89 means EnviraCom communication has been lost between the boiler control and certain Crown control…Communication lost between the boiler control and a Crown control option›

All Crown Boiler boiler models & codes →