What the 55 code means
Error 55 means the vent damper failed to open after 60 seconds. The boiler will not fire with the damper closed, so the start stops and the code sets. A loose or defective damper harness, an obstruction in the damper blade's path, a defective damper, or a defective control are the listed causes.
Likely causes
- Loose or defective damper harness
- Obstruction in the path of the damper blade
- Defective vent damper
- Defective control
How to fix it — step by step
- Record the code before resetting anything: write down the display exactly as shown (55) and whether the boiler was in a heating call, a hot-water call, or idle when it appeared.
- Safety: turn the thermostat down, switch off power to the boiler at the service switch and breaker, and close the manual gas shutoff if you smell gas or see scorching. Do not open the burner compartment if you smell gas; leave and call the gas supplier.
- Locate the part: the vent damper is in the flue outlet at the top of the boiler; its harness runs down to the boiler control.
- Test: inspect the damper blade path for obstruction and reseat the damper harness at both ends, then start a call and watch the blade. A blade that never gets power points to the harness or control; a powered blade that cannot move condemns the damper motor.
- End at the pinpoint: clear the obstruction or replace the Vent damper or its harness as the checks condemn; if all prove good, replace the boiler Control. Technician work. → Shop the vent damper at Amazon
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Vent damper.
Shop the Vent damper at Amazon
Also tied to this fault: Boiler control - Shop at Amazon
Parts that commonly fix the 55 code
- Vent damperShop at Amazon
- Boiler controlShop at Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.