Trane Furnace 12 flashes

What this problem usually means

On Trane two-stage furnaces (XV80, XV90, XV95, XL80, XL90 families, *UD2/*DD2) the green LED counts the fault: igniter failure — the igniter circuit did not perform as expected during the ignition sequence.

Likely causes

  1. Cracked or burned-out hot surface igniter
  2. Loose igniter connector
  3. Failed igniter output on the control board

How to fix it — step by step

  1. Confirm the thermostat is calling for heat
  2. Reset power once and listen: inducer runs but no glow or ignition points to the igniter
  3. Stop after one reset if the code returns
  4. Call a technician to test and replace the igniter

Parts that commonly fix it

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Related Trane furnace problems

See all Trane furnace codes & guides →