Trane Furnace 5 flashes
What this problem usually means
Trane uses this flash count on two different control families, so note which LED is flashing (red LED = single-stage control; green LED = two-stage control). On single-stage furnaces (XR80, XR90, XR95, XB80, XB90 families) with the integrated furnace control (IFC), 5 flashes means flame sensed when no flame should be present — the control sees a flame signal while the gas valve should be closed, which is a safety fault. On two-stage furnaces (XV80, XV90, XV95, XL80, XL90 families, *UD2/*DD2), 5 flashes means an open rollout switch or an open control fuse.
Likely causes
- Single-stage models: gas valve leaking or stuck open
- Single-stage models: shorted or damaged flame sensor wiring
- Single-stage models: failed control board misreading the flame signal
- Two-stage models: flame rollout from a blocked or cracked heat exchanger
- Two-stage models: blocked venting causing a rollout trip
- Two-stage models: blown control board fuse from a low-voltage short
How to fix it — step by step
- Turn the furnace power switch off and close the gas shutoff to the furnace
- Do not keep resetting or trying to run the furnace — both meanings of this code are safety faults, and a tripped rollout switch can signal a dangerous heat exchanger problem
- If you smell gas, leave the house and call the gas utility from outside
- Call a technician to find the cause before the furnace runs again
Parts that commonly fix it
- gas valve - Shop at RepairClinic
- flame sensor - Shop at RepairClinic
- control board - Shop at RepairClinic
- rollout switch - Shop at RepairClinic
- control board fuse - Shop at RepairClinic
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.