Trane Furnace 2 flashes

What this problem usually means

Trane uses this flash count on two different control families, so note which LED is flashing (red LED = single-stage control; green LED = two-stage control). On single-stage furnaces (XR80, XR90, XR95, XB80, XB90 families) with the integrated furnace control (IFC), 2 flashes means system lockout — ignition retries or recycles were exceeded, so the furnace tried to light several times, failed, and locked out. On two-stage furnaces (XV80, XV90, XV95, XL80, XL90 families, *UD2/*DD2), 2 flashes instead means a pressure switch stuck closed or an inducer error.

Likely causes

  1. Single-stage models: failed or cracked hot surface igniter
  2. Single-stage models: dirty flame sensor not proving flame
  3. Single-stage models: gas supply off or low gas pressure
  4. Two-stage models: pressure switch stuck closed
  5. Two-stage models: moisture or debris in the pressure switch or its hose
  6. Two-stage models: inducer motor fault

How to fix it — step by step

  1. Note the code and which LED is flashing before resetting, because a power cycle erases it
  2. Confirm the thermostat is set to Heat and calling for heat
  3. Check that the gas shutoff valve to the furnace is open and other gas appliances work
  4. Check outdoor vent and intake terminations for snow, ice or debris, and check the condensate drain for clogs or freezing
  5. Replace a dirty air filter, which can contribute to shutdowns
  6. Turn furnace power off for 30 seconds and back on once to clear the lockout; if the code returns, stop resetting and call a technician

Parts that commonly fix it

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.