Trane Furnace 10 flashes

What this problem usually means

On Trane two-stage furnaces (XV80, XV90, XV95, XL80, XL90 families, *UD2/*DD2) the green LED counts the fault: gas flow with no call for heat — the control detects gas flow or a gas valve output when the thermostat is not calling for heat.

Likely causes

  1. Gas valve stuck open or leaking through
  2. Control board gas valve relay stuck closed

How to fix it — step by step

  1. Turn furnace power off and close the gas shutoff valve to the furnace
  2. If you smell gas, leave the house and call the gas utility from outside
  3. Do not try to restart the furnace
  4. Call a technician immediately to test the gas valve and control board

Parts that commonly fix it

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.