Ruud Heat pump RHPBZR Series heat pumps - Enhanced Feature Demand Defrost Control LED 1 ON / LED 2 ON Error Code

What the LED 1 ON / LED 2 ON code means

Read on the two diagnostic LEDs of the Enhanced Feature Demand Defrost Control inside the outdoor unit, as charted in the Ruud RHPBZR installation instructions. Both LEDs on steady is the chart's 'Coil Sensor Failure'. The manual locates this sensor on the outdoor coil, on the topmost cross-over tube near the distribution tubes, and states plainly that if the coil sensor fails, the defrost control will not initiate a defrost. Because demand defrost needs the coil temperature to know when frost is forming, a failed coil sensor means the coil can ice over unchecked in heating, with airflow and heating capacity falling away.

Likely causes

  1. Coil sensor failed open or shorted
  2. Sensor unplugged, or its lead damaged or corroded at the board
  3. Sensor displaced from the top cross-over tube of the outdoor coil
  4. Failed defrost control board sensor input

How to fix it — step by step

  1. Record the code first: photograph LED 1 and LED 2 both on steady before cycling power.
  2. Safety: turn power off at the outdoor disconnect and the breaker, verify dead with a meter, and observe capacitor caution before touching wiring.
  3. Locate the part: per the manual, the coil sensor is on the outdoor coil near the point fed by the distribution tubes from the expansion device, on the topmost cross-over tube, and plugs into the defrost board in the control box.
  4. Test: unplug the sensor and measure its resistance against the manual's sensor temperature vs. resistance table - about 10,000 ohms at 77 F, about 32,650 ohms at 32 F. Open, shorted or far off-table readings condemn the sensor; a correct reading points to the harness or board.
  5. End at the fix: replace the defrost sensor if out of range, refit it firmly to the coil tube, restore power and confirm the LEDs return to normal and a test defrost (shorting the TEST pins on a heating call) initiates.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the LED 1 ON / LED 2 ON code

Parts run $25–$80

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.

Related Ruud Heat pump RHPBZR Series heat pumps - Enhanced Feature Demand Defrost Control error codes

See all Ruud RHPBZR Series heat pumps - Enhanced Feature Demand Defrost Control codes & guides →