Ruud Heat pump RHPBZR Series heat pumps - Enhanced Feature Demand Defrost Control LED 1 FLASH / LED 2 OFF Error Code
What it should look like on your machine
then it repeats
1 flash - then the pattern repeats. Count along with your machine and compare.
What the LED 1 FLASH / LED 2 OFF code means
Read on the two diagnostic LEDs of the Enhanced Feature Demand Defrost Control inside the outdoor unit, as charted in the Ruud RHPBZR installation instructions. LED 1 flashing with LED 2 off is the chart's 'High Pressure Lockout (short test pins to reset)'. The manual describes the control's high and low pressure inputs and microprocessor pressure-switch logic as providing compressor and system protection without nuisance lockouts. A high-pressure lockout therefore means discharge pressure rose high enough, repeatedly, that the control shut the compressor and outdoor fan down and is holding them off - a protective state that will keep returning until the pressure cause is corrected.
Likely causes
- Dirty or blocked outdoor coil restricting heat rejection in cooling
- Outdoor fan motor not running or running weakly
- Refrigerant overcharge
- Poor indoor airflow driving head pressure up in heating
How to fix it — step by step
- Record the code first: note LED 1 flashing / LED 2 off and the operating mode before resetting anything.
- Safety: turn power off at the outdoor disconnect and the breaker, verify dead with a meter, and observe capacitor caution. Refrigerant-side work is EPA-certified tech only.
- Locate the parts: inspect the outdoor coil through the grille for dirt and blockage, and the outdoor fan motor and run capacitor in the fan deck and control box.
- Test: clean the coil and confirm the fan runs at full speed on a call; a technician then measures discharge pressure and verifies charge - genuinely high pressure pinpoints airflow or charge, while normal pressure with repeat trips condemns the pressure switch or board.
- End at the fix: correct the airflow, fan or charge cause, then reset per the chart by shorting the test pins, and monitor a complete cycle for repeat trips.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Outdoor fan motor.
Shop the Outdoor fan motor at Amazon
Also tied to this fault: Run capacitor - Shop at Amazon; Defrost control board - Shop at Amazon
Parts that commonly fix the LED 1 FLASH / LED 2 OFF code
- Outdoor fan motorShop at Amazon
- Run capacitor$5–$35Shop at Amazon
- Defrost control boardShop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.
Related Ruud Heat pump RHPBZR Series heat pumps - Enhanced Feature Demand Defrost Control error codes
- LED 1 FLASH / LED 2 ON
- LED 1 OFF / LED 2 FLASH
- LED 1 OFF / LED 2 OFF
- LED 1 OFF / LED 2 ON
- LED 1 ON / LED 2 FLASH
- LED 1 ON / LED 2 ON
See all Ruud RHPBZR Series heat pumps - Enhanced Feature Demand Defrost Control codes & guides →