Ruud Heat pump RHPBZR Series heat pumps - Enhanced Feature Demand Defrost Control LED 1 FLASH / LED 2 ON Error Code
What it should look like on your machine
then it repeats
1 flash - then the pattern repeats. Count along with your machine and compare.
What the LED 1 FLASH / LED 2 ON code means
Read on the two diagnostic LEDs of the Enhanced Feature Demand Defrost Control inside the outdoor unit, as charted in the Ruud RHPBZR installation instructions. LED 1 flashing with LED 2 on steady is the chart's 'High Pressure Control Open'. This is the live event, distinct from the lockout pattern: the high pressure control has opened on excessive discharge pressure and the compressor and outdoor fan have stopped. The switch is automatic-reset, so the unit may restart as pressure falls, but the control's built-in pressure-switch logic counts repeated openings within a call - enough of them escalate this indication into a high-pressure lockout.
Likely causes
- Dirty or blocked outdoor coil in cooling
- Outdoor fan motor failed or not up to speed
- Refrigerant overcharge
- Poor indoor airflow in heating mode
How to fix it — step by step
- Record the code first: note LED 1 flashing / LED 2 on, the mode, and whether the outdoor fan was running when the unit stopped.
- Safety: turn power off at the outdoor disconnect and the breaker, verify dead with a meter, and observe capacitor caution. Refrigerant-side work is EPA-certified tech only.
- Locate the parts: inspect the outdoor coil for dirt and blockage, and the outdoor fan motor and run capacitor, reached from the top grille and control box.
- Test: wash the coil and confirm the fan starts and runs at full speed; a technician then measures discharge pressure - genuinely high pressure pinpoints airflow or charge, while an open switch at normal pressure condemns the switch or its wiring.
- End at the fix: correct the airflow, fan or charge cause (or replace a proven-bad pressure switch), restore power, and confirm a complete call with no reopening.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Outdoor fan motor.
Shop the Outdoor fan motor at Amazon
Also tied to this fault: Run capacitor - Shop at Amazon; Defrost control board - Shop at Amazon
Parts that commonly fix the LED 1 FLASH / LED 2 ON code
- Outdoor fan motorShop at Amazon
- Run capacitor$5–$35Shop at Amazon
- Defrost control boardShop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.
Related Ruud Heat pump RHPBZR Series heat pumps - Enhanced Feature Demand Defrost Control error codes
- LED 1 OFF / LED 2 FLASH
- LED 1 OFF / LED 2 OFF
- LED 1 OFF / LED 2 ON
- LED 1 ON / LED 2 FLASH
- LED 1 ON / LED 2 ON
- LED 1 FLASH / LED 2 OFF
See all Ruud RHPBZR Series heat pumps - Enhanced Feature Demand Defrost Control codes & guides →