Ruud Heat pump RHPBZR Series heat pumps - Enhanced Feature Demand Defrost Control LED 1 OFF / LED 2 ON Error Code

What the LED 1 OFF / LED 2 ON code means

Read on the two diagnostic LEDs of the Enhanced Feature Demand Defrost Control inside the outdoor unit, as charted in the Ruud RHPBZR installation instructions. LED 1 off with LED 2 on steady is the chart's 'Ambient Sensor Failure'. The manual locates the ambient air sensor outside the control box so it can sense outdoor temperatures, and gives the failure behaviour directly: if the ambient sensor fails, the defrost control falls back to initiating a defrost every 34 minutes of compressor run time whenever the coil temperature is below 35 F. The unit keeps heating, but defrost is now on a fixed timer rather than on measured need.

Likely causes

  1. Ambient sensor failed open or shorted
  2. Sensor unplugged, or its lead damaged or corroded at the board
  3. Sensor displaced from its position outside the control box
  4. Failed defrost control board sensor input

How to fix it — step by step

  1. Record the code first: note LED 1 off / LED 2 on and the outdoor temperature before cycling power.
  2. Safety: turn power off at the outdoor disconnect and the breaker, verify dead with a meter, and observe capacitor caution before handling wiring.
  3. Locate the part: per the manual, the ambient air sensor is located outside the control box so it can sense outdoor temperatures, with its lead running to the defrost board.
  4. Test: unplug the sensor and measure its resistance against the manual's sensor table - about 10,000 ohms at 77 F and about 32,650 ohms at 32 F. Open, shorted or badly off-table readings condemn the sensor; a correct reading shifts suspicion to the harness or board.
  5. End at the fix: replace the thermistor if out of range and mount it to sense outdoor air, restore power, and confirm the LEDs return to the normal pattern and defrost timing is demand-based again. → Shop the thermistor at Amazon

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the LED 1 OFF / LED 2 ON code

Parts run $25–$80

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.

Related Ruud Heat pump RHPBZR Series heat pumps - Enhanced Feature Demand Defrost Control error codes

See all Ruud RHPBZR Series heat pumps - Enhanced Feature Demand Defrost Control codes & guides →