Low water pressure

Low pressure is a symptom with two very different homes: a single clogged fixture, or the whole house being under-supplied. Branch on that first. Most 'low pressure' calls are one aerator. Then measure, because a $15 gauge separates a partly closed valve or a tired pressure-reducing valve from a city problem you cannot fix. If only the shower is weak, start with the shower pressure guide instead.

First checks: these apply to every brand

  1. Branch first: one fixture, one floor, or the whole house? — Run several fixtures before touching any valve. If only one faucet or shower is weak, the problem is at that fixture, an aerator, showerhead or its shutoff, not house pressure; see the shower pressure guide if it is the shower. If everything on one floor or one branch is weak, suspect a partly closed branch valve or a restriction in that run. Only if every fixture in the house is weak do you work through the rest of this guide: main valve, PRV and street supply, in that order.
  2. Measure the static pressure with a gauge — Buy or borrow a water pressure gauge with a hose thread. It screws by hand onto an outdoor hose bib or a laundry tap, the closer to where the main enters the house the better. Turn off every tap and appliance that uses water, open the bib fully and read the dial: that is static pressure. A normal house runs at about 40 to 60 psi, and the residential code maximum is 80 psi. Below about 40 psi every fixture feels tired; at or above 80 psi the pressure itself is the problem, stressing valves, supply lines and the water heater even if the showers feel great.
  3. Check the main shutoff is fully open — Find the main shutoff where the service line enters the house (and the curb/meter valve if it is accessible). A main or meter valve left partly closed after earlier work is a common, free fix: it lets a normal static reading build up but starves the house the moment several fixtures run, so pressure collapses in use. Open it fully, then re-test at a fixture. If the static reading was low but improves with the valve fully open, that was the cause.
  4. Find and test the pressure-reducing valve (PRV) — If the house has a PRV, it is a bell-shaped brass valve on the main line just after it enters the building, near the main shutoff. The common Watts LF25AUB model is adjustable from 25 to 75 psi with a standard factory setting of 50 psi. That 50 psi is the target most houses run. PRVs fail with age and the failure is usually a drift downward: the house slowly gets weaker over months or years. To adjust one, loosen the locknut on top of the valve, turn the adjusting screw clockwise to raise the downstream pressure or counterclockwise to lower it, making small turns and re-reading the gauge after each, and never set it above the valve's range or the 80 psi code maximum. If the gauge does not respond to adjustment, the PRV has failed and needs replacing. That is a plumber's job for most people.
  5. Decide whether it is the city's problem or old pipe — Ask a neighbour whether their pressure is also low, and check whether yours dropped suddenly or faded over years. Sudden and shared means the street supply: a utility main break, hydrant flushing or municipal work. That is the water utility's problem, and your gauge reading at the bib will be low with your main valve fully open and no PRV in the way. Slowly fading over years in an older house with galvanised steel pipe usually means the pipe itself: corrosion narrows galvanised pipe from the inside until no valve setting can restore flow, and the fix is repiping, not adjustment. A reading that is normal at the bib but collapses when two fixtures run together points the same way: restriction, not supply.

Which is yours?

Only one fixture is weak - That is not house pressure. Unscrew that faucet's aerator or that showerhead, rinse the debris screen and soak out limescale, and confirm the fixture's own shutoff valves are fully open.

The whole house is weak - Work the gauge, main valve and PRV checks in order. A normal static reading that collapses in use means a partly closed valve or a restriction; a low static reading means the PRV setting, a failed PRV, or low street pressure.

It dropped suddenly, everywhere, today - Check with a neighbour and the utility before opening anything up: a shared sudden drop is a street main problem. A sudden drop only at your house, with water running somewhere you cannot account for, can be a break in your own service line. Call a plumber.

More plumbing problems: Toilet won't flush · Toilet keeps running · Leaky faucet · Kitchen sink leaking · Sink won't drain · Tub or shower drain is slow · Garbage disposal won't run

Where is the pressure low?

The checks above fix most cases. For the causes, codes and parts specific to yours, pick your brand:

Parts that commonly fix it

When to call a pro: Call a plumber if the gauge reads normal pressure at the hose bib but fixtures are still weak (a hidden restriction or failing PRV under load), if adjusting the PRV changes nothing, if pressure is suddenly low everywhere at once, which can mean a main-line leak or break, or if you have no PRV and street pressure is over 80 psi. Call the water utility first if neighbours have the same problem or the low pressure started suddenly across the street.