Lennox Furnace DS1 slow flash, DS2 slow flash (alternating)

What this problem usually means

On Lennox furnaces with the two-LED SureLight control (DS1 red, DS2 green; G40, G50, G51, G60, G61 series), slow flashes alternating between DS1 and DS2 mean Watchguard lockout — burners failed to ignite, a limit stayed open over 3 minutes, flame was lost 5 times, or the pressure switch opened 5 times in one cycle. The furnace retries after about an hour.

Likely causes

  1. Failed igniter or dirty flame sensor (failed ignition)
  2. Restricted airflow holding a limit open
  3. Vent or drain problem opening the pressure switch repeatedly

How to fix it — step by step

  1. Write down this pattern and note anything the furnace did before locking out
  2. Check and replace a dirty air filter
  3. Check outdoor vents and the condensate drain for blockages
  4. Wait for the Watchguard hour or reset power once; if it locks out again, call a technician

Parts that commonly fix it

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Related Lennox furnace problems

See all Lennox furnace codes & guides →