Lennox Furnace DS1 slow flash, DS2 slow flash (alternating)
What this problem usually means
On Lennox furnaces with the two-LED SureLight control (DS1 red, DS2 green; G40, G50, G51, G60, G61 series), slow flashes alternating between DS1 and DS2 mean Watchguard lockout — burners failed to ignite, a limit stayed open over 3 minutes, flame was lost 5 times, or the pressure switch opened 5 times in one cycle. The furnace retries after about an hour.
Likely causes
- Failed igniter or dirty flame sensor (failed ignition)
- Restricted airflow holding a limit open
- Vent or drain problem opening the pressure switch repeatedly
How to fix it — step by step
- Write down this pattern and note anything the furnace did before locking out
- Check and replace a dirty air filter
- Check outdoor vents and the condensate drain for blockages
- Wait for the Watchguard hour or reset power once; if it locks out again, call a technician
Parts that commonly fix it
- hot surface igniter - Shop at RepairClinic
- flame sensor - Shop at RepairClinic
- pressure switch - Shop at RepairClinic
- limit switch - Shop at RepairClinic
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.