Lennox Furnace E240 Error Code

What the E240 code means

On newer Lennox furnaces (EL296, SL280, SLP98, ML296 and similar) showing three-digit codes from the Lennox Residential Communicating Systems Alert Code Guide, E240 means low flame current in run mode — the flame sensor signal is weak while the burners run.

Likely causes

  1. Dirty or oxidized flame sensor
  2. Poor burner ground
  3. Exhaust recirculating into the intake at the termination

How to fix it — step by step

  1. Replace the air filter and open all registers
  2. Check that the outdoor exhaust is not blowing back into the intake termination
  3. Note if the furnace short-cycles
  4. Call a technician to clean or replace the flame sensor and measure flame current

Parts that commonly fix the E240 code

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.