Lennox Furnace E240 Error Code
What the E240 code means
On newer Lennox furnaces (EL296, SL280, SLP98, ML296 and similar) showing three-digit codes from the Lennox Residential Communicating Systems Alert Code Guide, E240 means low flame current in run mode — the flame sensor signal is weak while the burners run.
Likely causes
- Dirty or oxidized flame sensor
- Poor burner ground
- Exhaust recirculating into the intake at the termination
How to fix it — step by step
- Replace the air filter and open all registers
- Check that the outdoor exhaust is not blowing back into the intake termination
- Note if the furnace short-cycles
- Call a technician to clean or replace the flame sensor and measure flame current
Parts that commonly fix the E240 code
- flame sensor - Shop at RepairClinic
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.