Lennox Furnace DS1 off, DS2 slow flash
What this problem usually means
On Lennox furnaces with the two-LED SureLight control (DS1 red, DS2 green; G40, G50, G51, G60, G61 series), DS1 off with DS2 slow flash means the low pressure switch is open — it failed to close, or was closed before the inducer started.
Likely causes
- Blocked intake or exhaust vent
- Clogged or frozen condensate drain
- Failed inducer motor
- Failed pressure switch
How to fix it — step by step
- Clear snow, ice or debris from the outdoor intake and exhaust
- Check the condensate drain for clogs or freezing
- Reset power once (off 30 seconds, then on)
- Call a technician if it returns, to test the inducer and pressure switch
Parts that commonly fix it
- pressure switch - Shop at RepairClinic
- inducer motor - Shop at RepairClinic
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.