Lennox Furnace DS1 slow flash, DS2 fast flash

What this problem usually means

On Lennox furnaces with the two-LED SureLight control (DS1 red, DS2 green; G40, G50, G51, G60, G61 series), DS1 slow flash with DS2 fast flash means a low flame signal (below 0.2 microamps) — the flame sensor signal is too weak.

Likely causes

  1. Dirty or oxidized flame sensor
  2. Poor burner ground
  3. Weak flame from dirty burners

How to fix it — step by step

  1. Replace the air filter and open all registers
  2. Note if the furnace runs but short-cycles
  3. Reset power once and observe a full cycle
  4. Call a technician to clean or replace the flame sensor and measure flame current

Parts that commonly fix it

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Related Lennox furnace problems

See all Lennox furnace codes & guides →