Lennox Furnace 2 + 7 Error Code

What the 2 + 7 code means

On Lennox G61MPV furnaces with the SureLight control, flash code 2 + 7 means the low pressure switch opened during the ignition trial or heating demand — draft was lost mid-cycle.

Likely causes

  1. Vent or intake becoming blocked during run
  2. Condensate backing up during run
  3. Failing inducer motor
  4. Intermittent pressure switch

How to fix it — step by step

  1. Clear the outdoor terminations of snow, ice or debris
  2. Check the condensate drain hose for clogs, kinks or freezing
  3. Reset power once and watch whether the furnace completes a cycle
  4. Call a technician if it recurs — mid-run draft loss needs inducer and vent testing

Parts that commonly fix the 2 + 7 code

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.