Lennox Furnace E270 Error Code
What the E270 code means
On newer Lennox furnaces (EL296, SL280, SLP98, ML296 and similar) showing three-digit codes from the Lennox Residential Communicating Systems Alert Code Guide, E270 is a Watchguard soft lockout — flame failed to ignite through all retries (five failed tries), so the furnace shut down and will retry after the Watchguard period.
Likely causes
- Failed hot surface igniter
- Dirty flame sensor
- Gas supply off or interrupted
- Dirty filter or blocked drain interrupting the sequence
How to fix it — step by step
- Confirm the gas shutoff is open and other gas appliances work
- Replace a dirty air filter and check the condensate drain
- Wait out the Watchguard or reset power once
- If it locks out again, call a technician to test the igniter, sensor and gas valve
Parts that commonly fix the E270 code
- hot surface igniter - Shop at RepairClinic
- flame sensor - Shop at RepairClinic
- gas valve - Shop at RepairClinic
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.