Lennox Furnace 5 + 1 Error Code

What the 5 + 1 code means

On Lennox G61MPV furnaces with the SureLight control, flash code 5 + 1 is a hard lockout — the rollout circuit is open or was previously opened. This is a safety lockout that will not auto-retry.

Likely causes

  1. Flame rollout from a blocked or cracked heat exchanger
  2. Blocked venting
  3. Tripped manual-reset rollout switch

How to fix it — step by step

  1. Turn the furnace off and leave it off
  2. Do not reset the rollout switch yourself — the cause must be found first
  3. Call a technician to inspect the heat exchanger and venting before the furnace runs again

Parts that commonly fix the 5 + 1 code

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.