Kenmore Dryer PS Error Code

What the PS code means

Power supply error on Kenmore 796-series (LG-built) electric dryers: the power cord is not connected correctly, for example the neutral (white) and L2 (red) wires are on the wrong terminals, so the control protects itself.

Likely causes

  1. Power cord wired incorrectly at the terminal block
  2. House power supply incorrect
  3. Loose power cord connection

How to fix it — step by step

  1. Turn off power at the breaker and unplug the dryer
  2. Check the power cord connection at the back of the dryer against the installation instructions
  3. Correct the wiring or have an electrician do it if you are not confident
  4. Restore power and try a cycle

Parts that commonly fix the PS code

This fault usually does not need a replacement part - the fix is in the steps above. If your machine does need a part, start with the link above.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Related Kenmore dryer error codes

See all Kenmore dryer codes & guides →