Goodman Furnace EE1 Error Code
What the EE1 code means
Pressure switch circuit closed at the start of a heat cycle on newer Goodman single-stage furnaces with the alphanumeric display control. The switch should be open before the inducer starts.
Likely causes
- sticking pressure switch contacts
- short in pressure switch wiring
- water in the pressure switch hose
How to fix it — step by step
- Check the thermostat is set to Heat and calling for heat
- Check the outdoor vent and intake pipes are clear of snow, ice or debris
- On a high-efficiency model, check the condensate drain line and trap are not clogged or frozen
- Turn power off at the furnace switch for 30 seconds, then back on, and try one heat call
- If the code returns, stop resetting and call a licensed HVAC technician
Parts that commonly fix the EE1 code
- pressure switch - Shop at RepairClinic
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.