Goodman Furnace 12 flashes

What this problem usually means

Inducer relay error or improper grounding on Goodman GMES96-series furnaces. The control cannot run the inducer relay correctly or detects a grounding problem.

Likely causes

  1. failed inducer relay on the control board
  2. poor or missing furnace ground
  3. faulty inducer motor circuit

How to fix it — step by step

  1. Check the thermostat is set to Heat and calling for heat
  2. Check the outdoor vent and intake pipes are clear of snow, ice or debris
  3. On a high-efficiency model, check the condensate drain line and trap are not clogged or frozen
  4. Turn power off at the furnace switch for 30 seconds, then back on, and try one heat call
  5. If the code returns, stop resetting and call a licensed HVAC technician

Parts that commonly fix it

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.