GE CleanSpeak GTD81 Series Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 9 codes covered.
Shop GE CleanSpeak GTD81 Series parts at RepairClinic or Amazon
- F01 — On GE CleanSpeak GTD81 dryers (technical service manual fault chart): Inlet thermistor short circuit. The manual advises replacing the…
- F02 — On GE CleanSpeak GTD81 dryers (technical service manual fault chart): Outlet thermistor short circuit - replace the thermistor or review…
- F03 — On GE CleanSpeak GTD81 dryers (technical service manual fault chart): Inlet thermistor open circuit - replace the thermistor or review its…
- F04 — On GE CleanSpeak GTD81 dryers (technical service manual fault chart): Outlet thermistor open circuit - replace the thermistor or review its…
- F05 — On GE CleanSpeak GTD81 dryers (technical service manual fault chart): EEPROM error - the manual says to replace the board.
- F06 — On GE CleanSpeak GTD81 dryers (technical service manual fault chart): Stuck button - set when a button is pressed longer than a minute; if…
- F07 — On GE CleanSpeak GTD81 dryers (technical service manual fault chart): Mis-wire - the neutral wire is improperly connected; ensure proper…
- F08 — On GE CleanSpeak GTD81 dryers (technical service manual fault chart): Door Switch Stuck Closed - set when the door has not opened for 5…
- F09 — On GE CleanSpeak GTD81 dryers (technical service manual fault chart): Long dry times - set when the dryer reaches its maximum cycle time…