Cummins QuietConnect RS13A / RS17A / RS20A / RS20AC (GSBB/GSBC) Common Problems
Find your problem in the list below. Each page explains the most likely causes, step-by-step checks you can do yourself, when to call a pro, and the parts that commonly resolve it. 14 problems covered.
Not sure of the code? Tap along with it
If your Cummins Generator blinks or beeps a pattern instead of showing a code, tap the button in time with each blink or beep. A pause longer than a second and a half starts a new group - we will match the rhythm to a code.
Your taps: -
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
| Problem | What it means | Check first | |
|---|---|---|---|
| Code 12 - Overvoltage | Generator output voltage rose above the safe limit and the set shut down. | Generator set loads | › |
| Code 13 - Undervoltage | Generator output voltage fell below the required level and the set shut down. On this controller the display… | Generator set loads | › |
| Code 14 - Overfrequency | Output frequency ran too high and the set shut down. Frequency follows engine speed, so this is a… | Engine governor function | › |
| Code 15 - Underfrequency | Output frequency fell too low and the set shut down. The engine is running slow for the load placed on it, or… | Too many connected loads, especially high starting-current loads such as air | › |
| Code 2 - Low Oil Pressure | Shutdown on loss of engine oil pressure, shown as two blinks on the status indicator light. The engine stops… | Oil level too low or too high | › |
| Code 29 - High Battery Voltage | Battery voltage is too high while charging. The charging side is pushing the starting battery above its… | Faulty battery charger | › |
| Code 32 - Low Cranking Speed Sense | The engine cranks too slowly to start cleanly. The controller senses low cranking speed and shuts the start… | Battery discharged or failing | › |
| Code 35 - Control Card Failure | Control card failure. The named cause is a faulty program, and there is no field correction for it. | Faulty control card program | › |
| Code 36 - Stopped Without Fault Condition | The generator set stopped without a fault condition being detected first. The engine was running and quit… | Fuel supply interrupted | › |
| Code 4 - Overcrank | Cranking time exceeded 35 seconds, shown as four blinks, and the engine never started. The controller stopped… | Fuel supply closed or empty | › |
| Code 79 - Failure to Transfer to Generator Set | The transfer switch failed to transfer the load to the generator set. The generator may run correctly while… | Generator set main AC circuit breaker off | › |
| Does Not Transfer | The generator runs but the house load does not transfer, or the load does not transfer back to utility. Two… | Transfer switch faulty | › |
| Won't Start | The set cranks but does not start, with no fault code shown, or it runs the battery down trying. Carbon… | Faulty or incorrect spark plugs | › |
| Won't Turn On | No response at all, and the status indicator light inside the generator set is dead. Work the branches in… | Low or no battery voltage | › |
All Cummins generator models & codes →
Once you know the part you need, browse Cummins QuietConnect RS13A / RS17A / RS20A / RS20AC (GSBB/GSBC) replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.