Chamberlain Garage door opener Security+ 2.0 / 3.0 4-3 Error Code
What the 4-3 code means
Code 4-3 (4 UP flashes, 3 DOWN flashes): RPM lost while closing. The door starts down, then stops and reverses just before it reaches the floor: the motor's speed dropped unexpectedly at the end of travel. Check first for anything interfering with the door's movement; if the path is clear, the travel module that tracks the door's position is the suspect.
Likely causes
- Debris or an object low in the tracks or at the floor line
- A binding roller or hinge near the bottom of travel
- Travel module / RPM sensing fault inside the opener
How to fix it — step by step
- Inspect the door path and especially the bottom of both tracks and the floor line - the reversal happens at the end of travel, so check where the door is when it quits.
- Remove any obstruction, check the rollers and hinges for wear or binding, and test the door again.
- If it now closes fully and the code clears, the interference was the fault. If 4-3 returns on a clear path, the opener's travel module or RPM sensing is failing to track the door - internal parts that a technician should confirm and replace.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the Travel module.
Parts that commonly fix the 4-3 code
- Travel module$30–$90Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.