Chamberlain Garage door opener Security+ 2.0 / 3.0 4-3 Error Code

What the 4-3 code means

Code 4-3 (4 UP flashes, 3 DOWN flashes): RPM lost while closing. The door starts down, then stops and reverses just before it reaches the floor: the motor's speed dropped unexpectedly at the end of travel. Check first for anything interfering with the door's movement; if the path is clear, the travel module that tracks the door's position is the suspect.

Likely causes

  1. Debris or an object low in the tracks or at the floor line
  2. A binding roller or hinge near the bottom of travel
  3. Travel module / RPM sensing fault inside the opener

How to fix it — step by step

  1. Inspect the door path and especially the bottom of both tracks and the floor line - the reversal happens at the end of travel, so check where the door is when it quits.
  2. Remove any obstruction, check the rollers and hinges for wear or binding, and test the door again.
  3. If it now closes fully and the code clears, the interference was the fault. If 4-3 returns on a clear path, the opener's travel module or RPM sensing is failing to track the door - internal parts that a technician should confirm and replace.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 4-3 code

Parts run $30–$90Typical pro repair $100–$500Fixing it yourself typically saves $10–$470

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.