Chamberlain Garage door opener Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 32 codes covered.
Not sure of the code? Tap along with it
If your Chamberlain Garage door opener blinks or beeps a pattern instead of showing a code, tap the button in time with each blink or beep. A pause longer than a second and a half starts a new group - we will match the rhythm to a code.
Your taps: -
Finding your model number: it is on the unit's rating plate.
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
All models
| Problem | What it means | Check first | |
|---|---|---|---|
| Broken Spring | The spring above the door - a torsion spring on most doors, or extension springs along the horizontal tracks… | Cycle fatigue - springs are rated for a set number of open/close cycles and break at | › |
| Closes Then Reverses | A Chamberlain door that starts down and comes back up is reversing for one of two reasons: the safety sensors… | Sensor beam broken partway down - a loose sensor, a vibrating bracket, or something low | › |
| Hums but Door Doesn't Move | A Chamberlain opener that hums (or clicks) and does not move the door is reporting that the motor cannot turn… | Broken or failing spring making the door too heavy | › |
| Keypad Programming | Programming a Chamberlain wireless keypad (Chamberlain 878MAX / KLIK-series) sets a 4-digit PIN in two… | New keypad never programmed, or the PIN forgotten | › |
| Opener Runs but Door Doesn't Move | The motor runs - you can hear it and see the chain or belt travel - but the door stays put: the opener has… | Emergency release pulled and the trolley never re-engaged | › |
| Remote Programming | Programming a Chamberlain remote pairs it to the opener's receiver through the Learn button: one press of… | New or replacement remote not yet paired to the opener | › |
| Remote Won't Work | When a Chamberlain remote stops working but the wall control still runs the door, the fault is in the remote… | Dead or incorrectly installed remote battery | › |
| Won't Close | A Chamberlain opener that will not close is, most of the time, reporting a safety sensor problem: the opener… | Blocked or misaligned safety sensors | › |
| Won't Open | A Chamberlain opener that will not open the door splits into three families: no response at all (power or… | Broken or failing door spring - the door has become too heavy to lift | › |
| Won't Turn On | A Chamberlain opener with no signs of life - no lights, no sounds, wall control dark - has lost power or lost… | Tripped breaker or GFCI outlet (garage outlets are commonly GFCI-protected, sometimes | › |
Learn-Button LED Models
| Problem | What it means | Check first | |
|---|---|---|---|
| 1 Flash | One flash of the diagnostic LED next to the Learn button, repeating: a broken or disconnected wire to a… | Sensor wire broken, cut or pulled out of a terminal | › |
| 2 Flashes | Two flashes of the Learn-button diagnostic LED, repeating: a wire to a safety sensor is shorted out, or the… | White and white/black sensor wires swapped at the opener or at a sensor | › |
| 3 Flashes | Three flashes of the Learn-button diagnostic LED, repeating: a door control (wall control) related error -… | A staple through the door control wire shorting it | › |
| 4 Flashes | Four flashes of the Learn-button diagnostic LED, repeating: the safety reversing sensors are slightly… | Receiving sensor knocked slightly out of aim | › |
| 5 Flashes | Five flashes of the Learn-button diagnostic LED, repeating: the opener detects no RPM - no motor rotation -… | Door out of balance or a broken spring above the door | › |
| 6 Flashes | Six flashes of the Learn-button diagnostic LED, repeating: motor circuit failure. The fix is blunt: replace… | Failed motor circuit on the receiver logic board | › |
Security+ 2.0 / 3.0
| Code | What it means | Check first | |
|---|---|---|---|
| 1-1 | Code 1-1 (1 UP flash, 1 DOWN flash): the safety sensors are blocked, misaligned, disconnected, or a sensor… | Something physically blocking the beam between the sensors | › |
| 1-2 | Code 1-2 (1 UP flash, 2 DOWN flashes): the safety sensor wires are reversed or shorted. Unlike 1-1, the door… | Sensor wires reversed at the sensors or at the opener (white and striped swapped) | › |
| 1-5 | Code 1-5 (1 UP flash, 5 DOWN flashes): RPM not detected - the opener commanded the motor but did not sense it… | Door mechanically stopped: binding, a manual lock engaged, or a broken spring making | › |
| 1-6 | Code 1-6 (1 UP flash, 6 DOWN flashes): unexpected door movement - the opener detected the door moving without… | Out-of-balance door - worn or incorrect springs no longer counterbalancing the door's | › |
| 2-1 | Code 2-1 (2 UP flashes, 1 DOWN): a logic board component failure. The logic board - the opener's main circuit… | A failed component on the logic board | › |
| 2-2 | Code 2-2 (2 UP flashes, 2 DOWN): a logic board component failure. The logic board - the opener's main circuit… | A failed component on the logic board | › |
| 2-3 | Code 2-3 (2 UP flashes, 3 DOWN): a logic board component failure. The logic board - the opener's main circuit… | A failed component on the logic board | › |
| 2-4 | Code 2-4 (2 UP flashes, 4 DOWN): a logic board component failure. The logic board - the opener's main circuit… | A failed component on the logic board | › |
| 2-5 | Code 2-5 (2 UP flashes, 5 DOWN): a logic board component failure. The logic board - the opener's main circuit… | A failed component on the logic board | › |
| 4-1 | Code 4-1 (4 UP flashes, 1 DOWN): resistance while closing. The opener sensed an unexpected change in motor… | An object in the door's path or in a track | › |
| 4-2 | Code 4-2 (4 UP flashes, 2 DOWN flashes): resistance while opening. The door stops before it is fully open… | Obstruction in the door path or tracks | › |
| 4-3 | Code 4-3 (4 UP flashes, 3 DOWN flashes): RPM lost while closing. The door starts down, then stops and… | Debris or an object low in the tracks or at the floor line | › |
| 4-4 | Code 4-4 (4 UP flashes, 4 DOWN flashes): RPM lost while opening. The door stops before it is fully open… | Obstruction or binding in the tracks or door hardware | › |
| 4-5 | Code 4-5 (4 UP flashes, 5 DOWN flashes): unrecognized travel module. The opener does not recognize the travel… | Wrong travel module installed for the opener model | › |
Wall-Mount Jackshaft (8500W / 98022 / 98032)
| Code | What it means | Check first | |
|---|---|---|---|
| 3-5 | Code 3-5 (3 UP flashes, 5 DOWN flashes) - wall-mount jackshaft openers only (8500W/RJO70, 98022/RJO101… | Cable tension monitor disconnected from the logic board terminals | › |
| 5-5 | Code 5-5 (5 UP flashes, 5 DOWN flashes) - wall-mount jackshaft openers only (8500W/RJO70, 98022/RJO101… | No myQ remote light installed or plugged in | › |