CodeWhat it meansCheck first
1-1Code 1-1 (1 UP flash, 1 DOWN flash): the safety sensors are blocked, misaligned, disconnected, or a sensor…Something physically blocking the beam between the sensors›
1-2Code 1-2 (1 UP flash, 2 DOWN flashes): the safety sensor wires are reversed or shorted. Unlike 1-1, the door…Sensor wires reversed at the sensors or at the opener (white and striped swapped)›
1-5Code 1-5 (1 UP flash, 5 DOWN flashes): RPM not detected - the opener commanded the motor but did not sense it…Door mechanically stopped: binding, a manual lock engaged, or a broken spring making›
1-6Code 1-6 (1 UP flash, 6 DOWN flashes): unexpected door movement - the opener detected the door moving without…Out-of-balance door - worn or incorrect springs no longer counterbalancing the door's›
2-1Code 2-1 (2 UP flashes, 1 DOWN): a logic board component failure. The logic board - the opener's main circuit…A failed component on the logic board›
2-2Code 2-2 (2 UP flashes, 2 DOWN): a logic board component failure. The logic board - the opener's main circuit…A failed component on the logic board›
2-3Code 2-3 (2 UP flashes, 3 DOWN): a logic board component failure. The logic board - the opener's main circuit…A failed component on the logic board›
2-4Code 2-4 (2 UP flashes, 4 DOWN): a logic board component failure. The logic board - the opener's main circuit…A failed component on the logic board›
2-5Code 2-5 (2 UP flashes, 5 DOWN): a logic board component failure. The logic board - the opener's main circuit…A failed component on the logic board›
4-1Code 4-1 (4 UP flashes, 1 DOWN): resistance while closing. The opener sensed an unexpected change in motor…An object in the door's path or in a track›
4-2Code 4-2 (4 UP flashes, 2 DOWN flashes): resistance while opening. The door stops before it is fully open…Obstruction in the door path or tracks›
4-3Code 4-3 (4 UP flashes, 3 DOWN flashes): RPM lost while closing. The door starts down, then stops and…Debris or an object low in the tracks or at the floor line›
4-4Code 4-4 (4 UP flashes, 4 DOWN flashes): RPM lost while opening. The door stops before it is fully open…Obstruction or binding in the tracks or door hardware›
4-5Code 4-5 (4 UP flashes, 5 DOWN flashes): unrecognized travel module. The opener does not recognize the travel…Wrong travel module installed for the opener model›