What the 4-4 code means
Code 4-4 (4 UP flashes, 4 DOWN flashes): RPM lost while opening. The door stops before it is fully open because the motor's speed dropped unexpectedly during the up travel. Start with whatever could interfere with the door's movement; if the door itself moves freely and balances correctly, the travel module is the remaining suspect.
Likely causes
- Obstruction or binding in the tracks or door hardware
- Door out of balance - a failing spring making the lift too heavy near the top
- Travel module / RPM sensing fault
How to fix it — step by step
- Inspect the door path and tracks, remove any obstruction, and check rollers and hinges for visible wear or binding. Test again.
- If the code returns, do the balance test: disconnect the opener with the door closed, lift the door by hand, and feel for a heavy or sinking door. Difficulty opening by hand, or a visible gap in the spring above the door, means a broken spring - stop and call a door technician; do not run the opener against a dead door.
- If the door opens and closes normally by hand and balances, reconnect the opener: the fault is in the travel module / RPM sensing inside the opener, a technician-level replacement.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the Travel module.
Parts that commonly fix the 4-4 code
- Travel module$30–$90Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.