State Water heater Won't Turn On

What this problem usually means

State's gas heaters in this catalog run on the same principle as their A. O. Smith siblings: the gas control has no house power at all — it runs on millivolts the thermopile generates from the pilot flame. A '0 flashes' reading, a dark status light, means the pilot is not lit and there is not enough millivolt power from the thermopile to keep it lit. That makes the diagnostic order fixed: pilot first, thermopile second, gas control last, and never the other way round. State's documented thermopile test is the centre of the page: measured open-circuit at the gas control with the pilot lit and the knob held down, a healthy thermopile reads roughly 350 to 850 millivolts; well under that with a good flame on the tip condemns the thermopile, and an in-range reading with a control that still won't hold the pilot condemns the gas control valve itself. On State ELECTRIC tanks the same dead-heater symptom follows the standard electric path: breaker, then the manual-reset high limit (ECO) behind the upper access panel, then the upper thermostat/element.

Likely causes

  1. Pilot out: no flame, no thermopile power, status light dark — State's '0 flashes' definition
  2. Weak or wandering pilot flame (clogged pilot orifice, poor draft) starving the thermopile of heat and therefore of voltage
  3. Failed thermopile: good flame on the tip but open-circuit output well under ~350 millivolts
  4. Loose thermopile wiring connector at the gas control valve
  5. Failed gas control valve: thermopile proven in range, control still will not hold the pilot or light its status light
  6. Electric models: tripped breaker, tripped high-limit (ECO) reset, or a failed upper thermostat/element

How to fix it — step by step

  1. Start at the gas control valve on the front of the tank and read the status light: dark means the control has no millivolt power at all — the pilot is out and the thermopile is making nothing. Do not start with electronics; work the pilot first. Also confirm the gas shutoff valve on the supply line is open and, on an electric State model, check the double-pole breaker in the panel instead (tripped = switch fully off, then on; trips again = leave it off)
  2. Relight the pilot following the lighting instructions printed on the front of the water heater, holding the knob down as directed. Watch the status light as the thermopile warms up: it should begin blinking once the thermopile is producing power. If it blinks, turn the knob to your temperature setting, confirm the main burner fires, and the job is done — the pilot had simply gone out
  3. Electric-model branch (no pilot, no status light system): with the breaker OFF, remove the upper access panel, fold back the insulation and press the red high-limit (ECO) reset button. A click means it had tripped after an overheat — restore the panel before re-energising, and treat a second trip as a failed thermostat or element, not a resetting exercise. No click = the ECO is innocent; the upper thermostat and upper element (behind the upper panel, the element screwed into the tank) are the pinpoint for the technician
  4. If the pilot will not stay lit or the light stays dark, judge the flame at the pilot assembly — it sits inside the burner compartment at the base of the tank, behind the outer burner door, and the thermopile is the generator tip standing in the pilot flame, wired up to the gas control. The flame should be strong, blue and enveloping the thermopile tip. A weak or wandering flame (clogged pilot orifice, poor draft) starves the thermopile of heat and therefore of voltage — cleaning the pilot orifice is the fix for that branch
  5. Test the thermopile this way (technician step, because the burner compartment is open): multimeter set to DC millivolts, thermopile's two wires disconnected at the gas control valve, pilot lit and knob held down, measure across the wires. Roughly 350–850 millivolts open circuit = healthy. Well under 350 with a good flame on the tip = the thermopile is worn out — it is replaced with the pilot assembly through the burner door → Shop the pilot assembly at Amazon → Shop the thermopile at Amazon
  6. If the thermopile reads in range but the control still will not hold the pilot or light its status light, the thermopile is proven and the gas control valve itself has failed — that is the pinpointed part, and its replacement is technician work (gas connections and a leak check are part of the job) → Shop the gas control valve at Amazon
  7. Verify after repair: status light blinking normally, pilot stays lit when the knob is released, the main burner fires when the temperature dial is turned up, and hot water recovers at the taps

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Typical pro repair $228–$1,017

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.