State Water heater 2 flashes
What it should look like on your machine
then it repeats
2 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
Insufficient power (millivolts) reaching the gas control valve/thermostat. The pilot may be lit, but the thermopile is not feeding the control enough voltage.
Likely causes
- Loose or corroded wiring connections in the thermopile circuit
- Failing thermopile in the pilot assembly
How to fix it — step by step
- The thermopile is in the pilot assembly behind the burner access door at the base of the tank, its two wires running up to the gas control valve/thermostat at the front of the tank.
- Check all wiring connections between the pilot/thermopile assembly and the gas control; reseat and clean any loose or corroded connection — a poor connection drops millivolts exactly like a dying thermopile.
- Test before replacing: with the pilot lit and its flame enveloping the thermopile tip, measure the thermopile's millivolt output at the control connections. A flame that is small, yellow or lifting off the tip is a pilot problem — clean the pilot orifice first. Full flame on the tip with output still too low to hold the control condemns the thermopile.
- If the problem persists, replace the thermopile assembly following the Replacing the Pilot/Thermopile Assembly procedure: gas control knob OFF, outer and inner burner doors off, thermopile wires disconnected at the control, the old thermopile unthreaded from its pilot bracket, the new assembly fitted with its tip in the same position in the flame, doors refitted, and the pilot relit per the label. → Shop the pilot/thermopile assembly at Amazon → Shop the thermopile at Amazon
- Prove it with a full heating cycle: pilot holds, burner fires, and the status light shows normal operation with no 2-flash code.
- If you hand it over, tell the technician: 2 flashes — insufficient millivolts at the gas control — and whether the connections were corroded and what the pilot flame looked like.
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the heater should run clean through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the thermopile.
Also tied to this fault: pilot/thermopile assembly - Shop at Amazon
Parts that commonly fix it
- thermopile$25–$80Shop at Amazon
- pilot/thermopile assembly$25–$80Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number