4 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
High water temperature has activated the overheat sensor. The control shut the burner and pilot down on high limit.
Likely causes
- Gas control valve/thermostat failed to stop heating at setpoint
- Overheat sensor tripped by a genuine over-temperature condition
How to fix it — step by step
- Understand what tripped: the gas control valve/thermostat at the front of the tank failed to stop heating at setpoint, or its overheat sensor caught a genuine over-temperature — either way the corrective action is the same part, and the heater stays off until it is replaced.
- Replace the gas control valve/thermostat: knob OFF, main gas OFF, tank drained, igniter and thermopile wires and the pilot and manifold tubes disconnected, the ground joint union broken, and the control turned out of the tank with a pipe section threaded into its inlet (never a wrench on the body). → Shop the gas control valve at Amazon
- Fit the new control in reverse with approved Teflon tape or pipe joint compound on the tank fitting, reconnect everything, turn the gas on and leak-test the supply connections, fill the tank completely, relight per the label, and leak-test the manifold and pilot connections with the burner lit (approved leak solution, or 1 part dish soap to 15 parts water — bubbles are a leak).
- Verify with a full heating cycle that stops at the setpoint temperature.
- If you hand it over, tell the technician: 4 flashes — overheat sensor tripped; the gas control valve/thermostat is the replacement part.
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the heater should run clean through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the gas control valve.
Parts that commonly fix it
- gas control valve$115–$500Shop at Amazon
- Tools for this job, if you need them$10–$20
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.