Ruud Heat pump Ruud variable-speed heat pumps with Variable Speed Outdoor Control (VSODC) and EcoNet 42 Error Code

What the 42 code means

Read as 42 on the dual 7-segment LED of the outdoor control, and as EcoNet fault T955_O at the EcoNet thermostat. Ruud's fault page identifies this as the compressor temperature (sump) thermistor: it is mounted under the compressor sound blanket, attached to the compressor belly with a large wire tie, and is used to monitor compressor temperature for stator heat operation and floodback protection. The system will run with this alert active and shows it as a current fault, but Ruud warns the sensor should not be left disconnected or failed, because older firmware revisions could leave the compressor without stator heat.

Likely causes

  1. Compressor sump thermistor failed open or shorted
  2. Thermistor strap loosened so the sensor lost contact with the compressor belly
  3. Sensor or its lead damaged under the sound blanket
  4. Sensor left disconnected after compressor service

How to fix it — step by step

  1. Record the code first: note code 42 (EcoNet T955_O) and that the unit may still be running, before cycling power.
  2. Safety: turn power off at the outdoor disconnect and the breaker, verify dead with a meter, and observe capacitor caution - the compressor shell can also be hot.
  3. Locate the part: lift the compressor sound blanket to find the thermistor strapped to the compressor belly with the large wire tie, about 4 inches up from the base per Ruud's page.
  4. Test: measure the thermistor's resistance against a 10K chart at the shell temperature; open or shorted readings condemn it. A good reading with the strap loose means refit it tightly to the belly and recheck. → Shop the thermistor at Amazon
  5. End at the fix: replace a failed sensor or restrap a sound one firmly to the compressor, restore power, and confirm code 42 clears - do not simply leave the sensor disconnected.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 42 code

Parts run $25–$80
  • Thermistor$25–$80Shop at Amazon
  • Tools for this job, if you need them$15–$65

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.