Ruud Heat pump Ruud variable-speed heat pumps with Variable Speed Outdoor Control (VSODC) and EcoNet 27 Error Code

What the 27 code means

Read as 27 on the dual 7-segment LED of the outdoor control board, one of the codes listed on Ruud's own 'Reading Alarms and Alerts on the outdoor control board' portal page, which notes the EcoNet thermostat is the ideal place to read the full fault. The code's Ruud name is 'Low Line Voltage': the outdoor control has measured the incoming line voltage to the unit as too low for reliable operation of the compressor and drive. Low voltage at start or under load risks failed starts and overheating, so the control flags it as a supply-side electrical fault rather than a refrigerant or sensor problem.

Likely causes

  1. Low supply voltage from the utility
  2. Loose line-voltage connections between breaker, disconnect and unit
  3. Undersized line conductors causing voltage drop under load
  4. Failing breaker or disconnect contacts

How to fix it — step by step

  1. Record the code first: note code 27 and whether it appears at start-up or during running, before cycling power.
  2. Safety: this is line-voltage diagnosis - turn power off at the outdoor disconnect and the breaker, verify dead with a meter, and observe capacitor caution; if you are not equipped for mains testing, stop and call a pro.
  3. Locate the parts: work the line-voltage path in order - breaker panel, outdoor disconnect, and the unit's line connections in the control box.
  4. Test: measure voltage at the unit at rest and during a start attempt; voltage that sags only under load pinpoints a loose connection or undersized run, while low voltage at rest points back toward the breaker, disconnect or utility.
  5. End at the fix: tighten or repair the connection, correct the conductor sizing or replace the failing device, then restore power and confirm clean starts with no repeat code.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 27 code

No specific replacement part is documented for this fault. If the checks above do not clear it, your heat pump likely needs to be disassembled and an internal part replaced - and since the manufacturer publishes no procedure for that, it is the point where most owners hand it to a repair shop.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.