Ruud variable-speed heat pumps with Variable Speed Outdoor Control (VSODC) and EcoNet Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 10 codes covered.
Not sure of the code? Tap along with it
If your Ruud Heat pump blinks or beeps a pattern instead of showing a code, tap the button in time with each blink or beep. A pause longer than a second and a half starts a new group - we will match the rhythm to a code.
Your taps: -
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
| Code | What it means | Check first | |
|---|---|---|---|
| 21 | Read as 21 on the dual 7-segment LED of the outdoor control, and as EcoNet fault A957_O (alarm) or T957_O… | System undercharged, typically from a refrigerant leak | › |
| 27 | Read as 27 on the dual 7-segment LED of the outdoor control board, one of the codes listed on Ruud's own… | Low supply voltage from the utility | › |
| 28 | Read as 28 on the dual 7-segment LED of the outdoor control board, one of the codes listed on Ruud's own… | High supply voltage from the utility | › |
| 29 / L29 | Read as 29, or L29 once locked out, on the outdoor control (shown on the VSODU), and as EcoNet fault… | Refrigerant overcharge | › |
| 35 | Read as 35 on the dual 7-segment LED of the outdoor control board, one of the codes listed on Ruud's own… | Suction thermistor failed open or shorted | › |
| 36 | Read as 36 on the dual 7-segment LED of the outdoor control, and as EcoNet fault A956_O at the EcoNet… | Suction pressure transducer disconnected | › |
| 42 | Read as 42 on the dual 7-segment LED of the outdoor control, and as EcoNet fault T955_O at the EcoNet… | Compressor sump thermistor failed open or shorted | › |
| 83 | Read as 83 on the dual 7-segment LED of the outdoor control board, one of the codes listed on Ruud's own… | Coil thermistor failed open or shorted | › |
| 84 | Read as 84 on the dual 7-segment LED of the outdoor control (VSODC), and as EcoNet fault T952_O at the EcoNet… | Outdoor temperature thermistor loose at its connection just below the control board | › |
| d1 | Read as d1 on the seven-segment LED of the outdoor control (VSODC), and as EcoNet fault A951_O at the EcoNet… | Defective memory card | › |
All Ruud heat pump models & codes →
Once you know the part you need, browse Ruud variable-speed heat pumps with Variable Speed Outdoor Control (VSODC) and EcoNet replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.