What the F8 E3 code means
Overflow condition: the washer is overfilling or the control believes the water level is too high.
Likely causes
- Inlet water valves not shutting off water flow
- Water level pressure sensor fault on the main control board
How to fix it — step by step
- Turn off the water supply faucets if the washer is actually overfilling
- Unplug the washer and check whether water keeps entering the tub
- If water enters with the washer off, the inlet valve assembly needs replacing → Shop the water inlet valve at RepairClinic
- If the washer is not actually overflowing, call for service for the main control board → Shop the main control board at RepairClinic
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the water inlet valve.
Shop the water inlet valve at RepairClinic or Amazon
Also tied to this fault: main control board - Shop at RepairClinic or Amazon
Parts that commonly fix the F8 E3 code
- water inlet valve - Shop at RepairClinic or Amazon
- main control board - Shop at RepairClinic or Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Maytag manual is on Maytag's support site — you'll need your model number.
Find your model number inside the door rim or on the back panel. It's the key to the right manual pages and the right parts.