Linear Garage door opener LDCO800 7 Flashes

What it should look like on your machine

then it repeats

7 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Limit error — the encoder has detected an error, or the down limit is set above the up limit. From the LDCO800 troubleshooting table.

Likely causes

  1. Open and close limits set wrong (down limit above up limit)
  2. Encoder detecting an error during travel

How to fix it — step by step

  1. Re-set the open and close limits (Section 13): for the open limit, move the door to the open position, press both UP and LEARN for three seconds (green indicator and light flash twice then stay on), jog with UP/DOWN if needed, then press LEARN to store (flashes two times). Repeat for the close limit with DOWN and LEARN (red indicator)
  2. Run the door through complete cycles and perform the Safety Reversal System Test after the limit reset
  3. If the 7-flash error occurs again after a correct limit reset, the remedy is to call the Technical Services Group — the encoder is the pinpoint

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Linear Garage door opener LDCO800 problems

See all Linear LDCO800 codes & guides →