Linear Garage door opener LDCO800 1 Flash
What it should look like on your machine
then it repeats
1 flash - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
No problem — a remote control was entered into memory. This is the LDCO800 confirmation flash, not a fault.
Likely causes
- Normal confirmation after adding a MegaCode remote
How to fix it — step by step
- No action is needed for the flash itself: the operator's light and red light flash once when a remote is added
- Add any additional remote controls the same way (MegaCode type only): press LEARN, then send a signal from the remote while the red light is on (about 15 seconds)
- Test each remote on a full open and close before relying on it
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the remote control.
Parts that commonly fix it
- remote control$20–$45Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.