Linear Garage door opener LDCO800 2 Flashes

What it should look like on your machine

then it repeats

2 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Door won't close — shorted wall station wires. From the LDCO800 troubleshooting table (Section 20).

Likely causes

  1. Wall station wires shorted together
  2. A staple compressing the wall station wire
  3. A wall station wire off its terminal screw

How to fix it — step by step

  1. Locate the flash count: the operator's lamp flashes when a command fails; 2 flashes is this code
  2. At the back of the operator, check the wall station wires at the terminal screws — external wiring only. Be sure both wires are connected to the terminal screws
  3. Follow the wall station wire run and check for a staple compressing the wire; remove any staples compressing it and separate any wires touching bare-to-bare
  4. Retest a close: a door that now closes had a shorted/loose wall station wire. If the wiring is proven sound and 2 flashes persist, the wall station itself is the pinpoint

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.