Linear Garage door opener LDCO800 2 Flashes
What it should look like on your machine
then it repeats
2 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
Door won't close — shorted wall station wires. From the LDCO800 troubleshooting table (Section 20).
Likely causes
- Wall station wires shorted together
- A staple compressing the wall station wire
- A wall station wire off its terminal screw
How to fix it — step by step
- Locate the flash count: the operator's lamp flashes when a command fails; 2 flashes is this code
- At the back of the operator, check the wall station wires at the terminal screws — external wiring only. Be sure both wires are connected to the terminal screws
- Follow the wall station wire run and check for a staple compressing the wire; remove any staples compressing it and separate any wires touching bare-to-bare
- Retest a close: a door that now closes had a shorted/loose wall station wire. If the wiring is proven sound and 2 flashes persist, the wall station itself is the pinpoint
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the wall station.
Shop the wall station at Amazon
Also tied to this fault: wall station wire - Shop at Amazon
Parts that commonly fix it
- wall stationShop at Amazon
- wall station wireShop at Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.