Goodman Furnace 2 flashes
What this problem usually means
Pressure switch stuck closed on Goodman GMES96-series furnaces. The control found the pressure switch closed at startup when it should be open, so it will not start the inducer sequence.
Likely causes
- pressure switch contacts stuck closed
- water or debris in the pressure switch hose
- faulty pressure switch
- inducer or control fault
How to fix it — step by step
- Check the thermostat is set to Heat and calling for heat
- Check the outdoor vent and intake pipes are clear of snow, ice or debris
- On a high-efficiency model, check the condensate drain line and trap are not clogged or frozen
- Turn power off at the furnace switch for 30 seconds, then back on, and try one heat call
- If the code returns, stop resetting and call a licensed HVAC technician
Parts that commonly fix it
- pressure switch - Shop at RepairClinic
- inducer motor - Shop at RepairClinic
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.