ecobee Thermostat Not Heating

What this problem usually means

An ecobee that will not heat splits into 'not requesting heat' versus 'requesting heat but no heat.' Requesting heat is shown by an orange flame icon or an orange line around the perimeter. If it is not requesting: confirm the mode is Auto, Heat or Aux, and that the Heat Differential has been reached (the room must be below the setpoint by 0.6–1°F by default) — and on a heat pump with no auxiliary heat, the Compressor Min Outdoor Temperature threshold (default 35°F) stops the heat pump being requested below it. ecobee's deciding test is Test Equipment mode, which takes settings out of the picture.

Likely causes

  1. System mode not on Heat, Auto or Aux
  2. Heat Differential not yet reached — room not far enough (0.6–1°F by default) below the setpoint
  3. Heat-pump lockout: outdoor temperature below the Compressor Min Outdoor Temperature threshold (default 35°F) on a system with no auxiliary heat
  4. Loose thermostat wiring or a configuration that does not match the wiring (ecobee's next check when it requests heat but nothing runs)
  5. Furnace-side fault: furnace breaker tripped, furnace error code/indicator lit, or furnace overheating (high-limit) shutting heating down — check/replace a clogged air filter first

How to fix it — step by step

  1. Read the thermostat's own signal first: orange flame icon or orange perimeter line means it IS requesting heat — skip the settings checks and go to the wiring/equipment steps. A white flame means it is not requesting
  2. Run ecobee's equipment test: Main Menu > General > Settings > Installation Settings > Test Equipment (Lite/Essential: Main Menu > Settings > Installation Settings > Test Equipment). For a furnace select Heat Stage 1 On for two minutes and check the vents for warm airflow; for a heat pump select Heat Pump Heat Stage 1 On and confirm the outdoor unit runs and vent air is warm; test Aux Stage 1 the same way if fitted. Heat in test mode proves the equipment works and the fault is a setting
  3. If test mode gives heat, fix the setting: confirm mode is Auto/Heat/Aux, and understand the differential — set the heat a few degrees above the room temperature for the test so the 0.6–1°F differential is unambiguously crossed. On a heat pump with no aux heat, check Installation Settings > Thresholds > Compressor Min Outdoor Temperature against the outdoor temperature
  4. Turn power to the HVAC system OFF at the breaker or furnace switch before you pull the thermostat off its wall plate or touch any wiring — that is the makers' own warning on this work.
  5. If test mode gives no heat: pull the ecobee gently off the wall, tug each wire, and reseat any loose wire by pressing its tab, sliding it out and back in. Photograph the wiring, refit the thermostat, then check Installation Settings > Equipment > Wiring — the highlighted wires must match the photo; if not, use Reconfigure Equipment to correct it, then re-run the test
  6. If wiring and configuration are correct and there is still no heat, check the equipment: furnace breaker on, any furnace error lights/codes (read them against the furnace manual), and the air filter — ecobee names reduced airflow from a clogged filter as a common overheating cause, and an overheated furnace shuts heating (and, on electric furnaces, the ecobee's power) down until it cools. A clean filter with continuing shutdowns is a technician's job — that is the pinpoint

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $70–$280

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manufacturer documentation

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related ecobee Thermostat problems

See all ecobee thermostat codes & guides →